background image

 

 

 

Mastervolt B.V.  
Snijdersbergweg 93 
1105 AN Amsterdam 
The Netherlands 
 
Tel.:   +31-20-3422100  
Email:  [email protected]  
Web:  www.mastervolt.com 

C

opy
right
 ©

 2

018 
M

as

ter

vol

t. A

ll r

ight

s r

es

er

ved.

 

R

epr
odu
ction,
 trans
fer

, d

istr

ibut

ion

 or

 s

tor

age of
 par
t or

 a

ll o

f t

he 
cont
ent
s i

thi

s do
cu

m

ent
 in any

 for

m

 

w

ithout
 the 
pr

ior

 w

ritt

en per

m

iss

ion

 of

 M

as

ter

vol

t is

 pr

oh

ibi

ted

.

 

Содержание AC Master 12/300

Страница 1: ...AC Master 12 300 12 500 24 300 24 500 PURE SINE WAVE INVERTER USER AND INSTALLATION MANUAL 1000014304 01 To download this manual in other languages please visit our website www mastervolt com...

Страница 2: ...Installation Manual Table of contents 1 Safety instructions 3 2 Liability 3 3 Disclaimer 3 4 Warranty 3 5 Correct disposal of this product 3 6 Product description 4 7 Installation instructions 5 8 Ope...

Страница 3: ...Disclaimer Our products are subject to continual development and improvement Therefore additions or modifications to the products may cause changes to the technical data and functional specifications...

Страница 4: ...e wave inverter The AC Master converts DC power from the battery into AC output power Identification label Part number Serial number J821A0001 with device version A Important information required for...

Страница 5: ...DC fuse s 3 DC input cables 1 5m 4 Chassis ground terminal M6 5 AC output socket IEC 7 Installation instructions This section provides a step by step instruction of the basic installation of the AC Ma...

Страница 6: ...that airflow through the ventilation openings is guaranteed Mounting the AC Master in another position is possible but influences the ingress protection degree IP No objects are to be located within...

Страница 7: ...tallation The neutral conductor N of the AC output of the AC Master must be connected to the safety ground PE GND Integrate a ground fault circuit interrupter GFCI RCD in the wiring of the AC output R...

Страница 8: ...detected higher than the threshold value the inverter is switched on Switching OFF Move the main switch to the position O OFF Note that switching off the AC Master does not disconnect the batteries LE...

Страница 9: ...attempts restarting 5 times If it still fails the AC Master remains in Overload Reduce the load and or check the AC wiring for possible short circuits Then reset the inverter manually by switching the...

Страница 10: ...g Approvals CE E mark CE E mark Technical Technology High frequency High frequency DC input voltage range 10 0 15 5V 20 0 31 0V Low battery voltage switches off at 10 0V 3 20 0V 3 Low battery voltage...

Страница 11: ...ls CE E mark CE E mark Technical Technology High frequency High frequency DC input voltage range 10 0 15 5V 20 0 31 0V Low battery voltage switches off at 10 0V 3 20 0V 3 Low battery voltage switches...

Страница 12: ...0 3422100 Email info mastervolt com Web www mastervolt com Copyright 2018 Mastervolt All rights reserved Reproduction transfer distribution or storage of part or all of the contents in this document i...