 18 

 

ENGLISH 

 

Parallel configuration 

 

DIP switch 4 

DIP switch 5 

DIP switch 6 

DIP switch 7 

Master 

0 0 0 1 

Slave 

0 0 1 1 

 

3 phase configuration 

 

DIP switch 4 

DIP switch 5 

DIP switch 6 

DIP switch 7 

Master 

(0°) 

0 0 0 1 

Slave 

(-120°) 

1 0 0 1 

Slave 

(120°) 

1 0 1 1 

 

LCM remote or DIP switch control select 

 

DIP switch 8 

LCM remote control ON 

DIP switch control ON 

 

 

Содержание AC Master 12/2500-230

Страница 1: ...AC Master PURE SINE WAVE INVERTER 12 2500 230 24 2500 230 12 3500 230 EN USER S AND INSTALLATION MANUAL 10000011809 00...

Страница 2: ...a sine wave inverter The AC Master converts DC energy from the battery into AC output power The AC Master 2500 3500 is equipped with an AC transfer switch and is suitable for creating systems with mul...

Страница 3: ...C output socket 10 Battery input 11 Battery input 12 LCM port for LCD remote control panel 13 DIP switches 14 LED indicator 15 Main switch 16 Hard wire connection for AC output and AC input 17 Interna...

Страница 4: ...4 AC Master Dimensions Model A mm B mm C mm D mm E mm F mm G mm H mm 2500 436 0 240 0 95 6 268 6 8 5 11 5 128 0 283 0 3500 496 0 240 0 125 6 268 6 8 5 11 5 128 0 283 0...

Страница 5: ...AC Master 5 Identification label...

Страница 6: ...0 3500 Please read the entire manual for instructions on safety grounding configuration settings additional features and creating systems with multiple units Read the safety instructions See section 1...

Страница 7: ...unt the AC Master with four screws to a solid surface 5 Connect the chassis ground terminal to the central grounding point of the vehicle ship 6 Optional Connect remote panel or remote switch see sect...

Страница 8: ...8 AC Master 7 Connect the battery to the DC input 8 Integrate a fuse holder in the positive battery wire but do not place the fuse yet...

Страница 9: ...AC Master 9 9 Connect the AC load See section 5 on page 12 for instructions on neutral grounding AC socket AC hard wired...

Страница 10: ...section 7 on page 16 11 Set the desired output voltage and other configuration settings see section 8 on page 16 12 Check all wiring If all wiring is OK Place the inverter fuse 13 Switch ON the AC Mas...

Страница 11: ...Master Possible errors in the included manual and the consequences of these Use that is inconsistent with the purpose of the product 3 Warranty Mastervolt assures the product warranty of the AC Maste...

Страница 12: ...ocation requirements the recommended wire sizes the optional remote panel and the remote switch are described in the following sections Choosing a location to install Install the AC Master in a well v...

Страница 13: ...rminal offers two functions Remote switch Install a switch for remote operation Make sure the main switch is at REMOTE position Jumper for CAN termination By connecting the jumper slots the CAN port c...

Страница 14: ...irectly connected to the load saving battery power The AC input is available on the hard wire terminal behind the front panel The inverter continuously checks if a mains power supply is available and...

Страница 15: ...ENGLISH 15 Bypass mode...

Страница 16: ...Power saving mode or Master Slave mode 8 LCM remote or DIP switch control AC output voltage setting Output voltage DIP switch 1 230 V 0 240 V 1 AC input mode Mode Inverter to Bypass mode when AC inpu...

Страница 17: ...ving is not available when the inverter is in Master Slave mode DIP switch 7 1 The Power Saving threshold value is set with DIP switch 4 5 and 6 Make sure that Power Saving Mode is selected DIP switch...

Страница 18: ...6 DIP switch 7 Master 0 0 0 1 Slave 0 0 1 1 3 phase configuration DIP switch 4 DIP switch 5 DIP switch 6 DIP switch 7 Master 0 0 0 0 1 Slave 120 1 0 0 1 Slave 120 1 0 1 1 LCM remote or DIP switch cont...

Страница 19: ...connections Tighten the connections burnt cables must be corrected immediately Flat battery Disconnect the load and recharge the battery Red Intermittent blinking Shutdown Internal temperature too hig...

Страница 20: ...Then reset the inverter manually by switching the main switch off and on again Red Intermittent blinking Shutdown Fan failure Contact your reseller Red Intermittent blinking Shutdown Hardware failure...

Страница 21: ...it see picture the main switch is OFF before you start configuring each unit DIP switch 7 and 8 are set to 1 for each unit each unit in the system is set to the same AC output voltage and frequency wi...

Страница 22: ...f the combined AC output to the safety ground PE GND externally Integrate a ground fault circuit interrupter GFCI in the combined AC output circuit Refer to locally applicable regulations regarding gr...

Страница 23: ...ENGLISH 23...

Страница 24: ...fault circuit interrupter GFCI in the combined AC output circuit Refer to locally applicable regulations regarding grounding of autonomous power systems The phases are connected in the correct order T...

Страница 25: ...ENGLISH 25...

Страница 26: ...0 V 20 0 V 32 0 V Low battery voltage switches off at 10 0 V 20 0 V Low battery voltage restart at 12 5 V 25 0 V High battery voltage switches off at 16 0 V 32 0 V High battery voltage restart at 15...

Страница 27: ...e range 10 0 V 16 0 V Low battery voltage switches off at 10 0 V Low battery voltage switches on at 12 5 V High battery voltage switches off at 16 0 V High battery voltage switches on at 15 0 V Input...