Mac Plus
–
User and Installation Manual
The
Mac Plus
can be configured as an
event source
. An event source can be used to initiate an
event command
and an
event action
by another device.
Event source
Meaning
Standby
Device state is Standby
Bulk
State of charge is Bulk
Absorption
State of charge is Absorption
Float
State of charge is Float
Alarm
Any of the alarms is triggered
When the
Mac Plus
is configured as an
event target
by another device, this device can initiate an
event command
and an
event action
to be performed by the
Mac Plus
.
Event command
Meaning
Standby
Command to switch on/off the Mac Plus. If the Mac Plus was switched off
by means of this event command, it will switch on again when it wakes
from sleep mode (i.e. after meeting the switch-on conditions, see DIP
switch/MasterBus settings).
Bulk
Command to start the Bulk state of charge
Absorption
Command to start the Absorption state of charge
Float