MasterBus – CANopen Interface / EN

 

 

4  Transfer data between MasterBus and CANopen 

 
The CANopen interface can transfer 100 data fields 
(values) between MasterBus and CANopen. This 
chapter describes how to configure these fields and 
shows some examples. 
The CANopen interface uses PDO messages to 
receive data from; and transmit data to the 
CANopen network. A PDO message is a CANopen 
message containing data. 
 

4.1 

CONFIGURE THE NUMBER OF DATA 
FIELDS  

Start by selecting the number of data fields you want 
to transfer. This can be configured on the 
configuration page at “Nr of fields”. 
 

4.2 

CONFIGURE THE DEVICE NUMBERS  

Select the number of devices on the MasterBus you 
want to communicate with. This can be configured 
on the configuration page at “Nr of devices”. 
Select the individual devices in the ‘Device numbers’ 
group. 
 
For example, if you want to connect to your Mass 
Combi Ultra and your MLI battery, you select Nr of 
devices = 2 and select in the Device numbers group 
the Mass Combi and the MLI battery.  
Now you can use these devices in the next steps of 
configuration. 
 

4.3 

DATA FIELD CONFIGURATION 
(STANDARD) 

To configure one of your data fields select the field 
number in the ‘Field config’ group. This loads the 
configuration for this field. Changes to the field 
configuration will take effect after you press the 
‘Save data field’ button. The following parameters 
can be changed in this group: 
 

 

COB-ID 

The PDO on CANopen uses this COB-ID. This COB-
ID is independent from the configured Node-ID. 
Minimum value is 0x181(hexadecimal), and the 
maximum value is 0x57F(hexadecimal) as defined 
by CANopen.  
By setting the same COB-ID multiple fields can be 
combined into one PDO. 
 

 

Byte 

Byte location of your data in the CANopen message. 
The PDO messages of the CANopen interface 
always contain 8 data bytes. The data bytes which 
do not contain data are set to 0xFF’. 
 
The ‘Byte’ setting allows you to place the information 
next to each other in the 8 data bytes.  
For example if you want to combine 2 floats in one 
message. Select ‘Byte’ 0 for the first data field and 4 
for the second data field (Floats require 4 bytes). If 
you want to combine 4 Signed integers select ‘Byte’ 
0, 2, 4 and 6 for the four data fields(16 bit Integers 
require 2 bytes). Floats and Signed integers can be 
combined in one PDO as well. 
 

 

Device 

Select any MasterBus device which has the 
information you want to connect to from the 
CANopen network. If you select for example “1” the 
device at “Device 1” in the ‘Device Indices’ group will 
be used for this data field. 
 

 

Page 

Select the page of the MasterBus device which has 
the information you want to connect to. Select 
Monitoring, Configuration, Alarm or the History page. 
 

 

Index 

Select the Index of the information you want to 
connect to. The Index can be found by hovering your 
mouse pointer over an item in MasterAdjust 
software. 
Figure 2 shows an example on how to find the index 
of a specific data field. 
 

 

Figure 2:  
Monitoring page of the MasterShunt, State of 
Charge has an Index of 0 

 

Содержание 77032600

Страница 1: ...pen Interface Interface between MasterBus and CANopen MASTERVOLT Snijdersbergweg 93 1105 AN Amsterdam The Netherlands Tel 31 20 3422100 Fax 31 20 6971006 www Mastervolt com Copyright 2016 Mastervolt 1...

Страница 2: ...h can be recycled and reused When this crossed out wheeled bin symbol is attached to a product it means the product is covered by the European Directive 2012 19 EU Please be informed about the local s...

Страница 3: ...l numbers base 16 This format is standard in CANopen All standard CANopen products will wait in the Pre operational state for a NMT Module Control message When a Start Remote Node Control message is r...

Страница 4: ...COB ID The PDO on CANopen uses this COB ID This COB ID is independent from the configured Node ID Minimum value is 0x181 hexadecimal and the maximum value is 0x57F hexadecimal as defined by CANopen By...

Страница 5: ...nfiguration parameters as in the configuration via the standard method but now combined into one string Meaning 285 This is the hexadecimal COB ID of the CANopen message Range 0x181 0x57F b0 Byte foll...

Страница 6: ...can now refer to Device 1 being the MasterShunt In the Field config group select data field 1 We leave all settings as default COB ID hex 285 Byte 0 Direction MB CANopen Device 1 Page Monitoring Index...

Страница 7: ...ata field button to save the configuration of data field 1 Make sure the option Auto start is still turned on The result The CANopen interface transmits out the heartbeat message every second No other...

Страница 8: ...ents COB ID Select the COB ID for the Event PDO Example If you want a CANopen product to react on an empty battery event of your MasterShunt battery monitor Select the following configuration In the M...

Страница 9: ...ive Event PDO option is checked the Interface will listen to a dedicated PDO with the data of 8 events COB ID The interface will listen to PDO messages with this COB ID Example To control the backligh...

Страница 10: ...See figure 8 for the CANopen Interface connections 1 CAN_High 2 CAN_Low 3 CAN_Ground 4 Communication LED for MasterBus and CANopen MasterBus 4 1 2 3 MasterBus network MasterBus network Figure 8 Overvi...

Страница 11: ...and CANopen Language English Current consumption 40 mA MasterBus Powering No Din rail mounting Yes Din rail 30 mm 1 2 inch Protection degree IP 21 Dimensions 66 x 78 x 32 mm 2 6 x 3 1 x 1 3 inch see F...

Страница 12: ...Snijdersbergweg 93 1105 AN Amsterdam The Netherlands Tel 31 20 3422100 Fax 31 20 6971006 Email info mastervolt com...

Отзывы: