4 TECHNICAL
INFORMATION
Model: Tanklevel
Interface
Article number:
77030300
Delivery also includes: Screw terminal, MasterBus cable, MasterBus Terminating device, User’s manual
Function of instrument: Processing tank level data for MasterBus, using a (non) powered electric sensor;
providing switched power to powered sensors
Battery voltage
0-63 V (< 200 mA), equals to the sensor supply voltage
Sensor voltage
0-70 V
Sensor resistance
0-300 Ohms
Sensor current
0 (4)-20 mA
Power consumption
280 mW
Languages available:
English,Nederlands,Deutsch,Français,Castellano,Italiano,Norsk,Svenska,Suomi, Dansk
Din rail mounting:
Yes, Din rail 30 mm [1.2 inch]
Protection degree:
IP 21
Dimensions:
66 x 78 x 32 mm [2.6 x 3.1 x 1.3 inch]; see drawing below
Weight:
Approx. 90 gr [0.20 lb] including screw terminal
5 EC DECLARATION OF CONFORMITY
This product is in conformity with the provision of the EC EMC directive 89/336/EEC
and amendments 92/31/EEC, 93/68/EEC. Standards applied:
Generic emission standard: EN 50081-1:1992,
Generic Immunity standard: EN 50082-1:1997,
Safety directive 2006/95/EC, with the following standard,
Low voltage standard: EN 60950: 2000.
Screw terminal
= MasterBus connector
Dimensions in mm (inch) and connections
4,5 [0.18]
69
[2.7]
4.0
[0.16]
33 [1.3]
33 [1.3]
6.0 [0.24]
78
[3.1]
32 [1.3]
4.0
[0.16]
Snijdersbergweg 93, 1105 AN Amsterdam, The Netherlands
Tel : + 31-20-3422100
Fax : + 31-20-6971006
Email : [email protected]