4.6 Advanced Settings
NOTE:
To access to this area is for fully qualified and accredited technicians only.
Enter menu “Advanced settings” (Initial password"1000").
YES=<ENT> NO=<ESC>
Password:0000
Figure 4.25 Enter password
4.6.1 Output Settings
This function is to control the output power on the load port.
On Backup ON/OFF , when choose ON, power can be allowed to export.
When choose OFF, power can't be allowed to export, default is ON.
Figure 4.26 Set Backup
After enter the correct password 1000 access to the following information
1. Output Settings
2. Battery Settings
3. Special Settings
4. Equalizer Settings
5. Password Settings
The screen can be scrolled by pressing the UP/DOWN keys.
Pressing the ENTER key gives access to a submenu.
Press the ESC key to return to the Main Menu.
Backup ON/OFF
Set Backup:
OFF
Backup setting needs to be set according to the connected load. Please set the backup
voltage (can be set from
V) and Backup frequency (can be set to 220V or 230V)
220V-230
according to the actual situation of the connected load.
Figure 4.27 Backup Settings
Display
Description
Buckup Frequency:
50.0Hz
Buckup Voltage:
230.0V
Voltage Droop:
Disable
Shows the
.
backup voltage
Shows the
.
backup frequency
Shows the
.
voltage droop
4.6.2 Battery Settings
This model of inverter can work compatible with both lithium-ion and lead acid batteries
Below is the compatibility list.
Table 4.1 Battery Select
4.6.2.1 Battery Select
BYD
Brand
Pylontech
Dyness
Select "B-BOX"
Setting
Select "Pylon"
Select "Dyness"
PREMIUM LVS, PREMIUMLVL,
Box Pro 2.5-13.8
Model
US2000/US3000
Powerdepot/Powerbox/B4850
The section has 4 parts:
1.
Battery Select
2. Battery W
akeup
3. Quick Charge
4. Battery detailed settings
4. Operation
4. Operation
.32.
.33.