PRODUCT INFORMATION
Part Number
Colour options (x)
Product Dimensions
Sockets
ELS134x
Black (B), Orange (O), White (W)
Height 31mm x Width 310mm x Depth 60mm
4
TECHNICAL SPECIFICATIONS
Standard(s)
Maximum Load (Wattage)
This product is certified to applicable British safety standards
BS 1363-2
13A: 3120 Watts, 240 Volts
IF IN DOUBT CONSULT A QUALIFIED ELECTRICIAN
FEATURES
• Heavy duty construction
• Rewireable
• Chunky solid cable entry guards
• Manufactured to BS1363-2
• Ideal for use with power tools, portable lighting and electrical appliances
• Four gang trailing socket made from industrial grade plastic
• Fitted with 13A replaceable fuse
• Easy access screw fixings for removing the back cover when rewiring
SAFETY WARNING
163
32.5
31
60
310
four gang trailing socket
WORK
4
SOCKETS
PLEASE READ CAREFULLY AND USE IN ACCORDANCE WITH OUR SAFETY
INSTRUCTIONS BELOW
The total maximum load must not exceed 13A/3120 Watts. Ensure that the plug to be
used in this unit is fitted with a fuse of the correct amperage as recommended by the
appliance manufacturer. The total power consumed by the appliance plugged into this
unit must not exceed 3120 Watts.
1. Use only 1.25mm² (13 amp) or 1.5mm² 3 core flexible cable. Use of smaller cable
could result in overheating.
2. Prepare cable as shown in Figure 1
3. Remove cover and cord grip
4. It is important to connect the correct coloured wire to the appropriate terminal as
shown in Figure 2 and ensure that all terminal screws are securely tightened.
5. Ensure that the cable sheath is securely clamped using the cord grip as shown in
Figure 2.
6. Replace the cover and tighten securely. The other end of the cable must be fitted
with a 13 amp plug fused at 13 amps (recommended Permaplug HDPT13).
An unfused plug must not be used.