10
OPERATION
2.5 To Start
2.5.1 Diesel Engine
—
Lombardini
1. Do not actuate starter for more than 20 seconds at a time. If engine does not start, wait
1 minute before repeating attempt. If engine does not start after two attempts, trace the
cause according to Diagnosis Chart.
2. Key always in on (1st) position when engine is running. Make sure that all the warning
lights are off when the engine is running. For engines with starting panel equipped
with engine protection, make sure the OK light only keeps ON.
1st position - Warning light on.
2nd Position - Starting.
3. After starting, at idle speed for a few minutes according to table:
Temperature Time
δ
- 20
°
C
5
’
- 20
°
C / - 10
°
C
2
’
- 10
°
C - 5
°
C
1
’
2.5.2 Petrol Engine
1. Open the fuel tap by moving the fuel ON/OFF
lever fully to the right.
2. If starting the engine from cold, set the choke ON
by moving the choke lever fully to the left. If
restarting a warm engine, the choke is usually not
required. However, if the engine has cooled to a
degree, partial choke may be required.
3. Turn the engine ON/OFF switch clockwise to the
“
1
”
position.
4. Set the throttle to the idle position by moving the throttle lever fully to the right. Do
not start the engine on full throttle, as the compactor will vibrate as soon as the
engine starts.