Masterlite 81265 Скачать руководство пользователя страница 2

STEP 1

Thank you for purchasing this light fitting.
Please read the instructions carefully before use to ensure safe and satisfactory operation of 
this product. Please retain these instructions for future reference.

Warning

Specification

Installation

Layout

Wiring

Voltage:  

240V 50Hz a.c.

Class: 

II (Double Insulated)

Lamp:  

3W LED Module - 6500K/280lm

 

IP rating:  

65

This  is a Class  11 product  and  must  not  be earthed.
Please read these instructions carefully before commencing any work.
This unit must be fitted by a competent and qualified electrician.
Install in accordance with IEE Wiring regulations and current Building Regulations.
To prevent electrocution switch off at mains supply before installing or maintaining this fitting. 
Ensure other persons cannot  restore the electrical supply without your knowledge. If you 
are in any doubt, please consult a qualified electrician.
This light fitting should be connected to a fused circuit.
If replacing an existing fitting, make a careful note of the connections.
This system contains non-replaceable parts and cannot be serviced. If damage occurs the part 
should be scrapped.
Waste electrical products should not be disposed of with household waste. Please recycle 
where facilities exist. Check with your local authority or retailer for recycling advice.

This product is rated at IP65
This  product is not suitable for location in or near a marine environment.
This product is not suitable for dimming.

 

Plan the desired layout of this fitting carefully, ensuring the cables will reach the distance 
between the junction box and the light fitting.

 

Avoid  locating  any  cables  in  positions  that  would  cause  a  hazard.  Position  cables  and 
outdoor rated junction boxes (not supplied) away from areas where they may be at risk 
from being cut, trapped or damaged.

 

We recommend that you use H05RN-F specification cable (not supplied) which is an 
outdoor  grade,  rubber  sheathed  cable. The  mains  supply  cable  must  have  a  minimum 
cross sectional area of 1.0mm²

 

Cables must be protected using suitable conduit or plastic trunking.

2. 

Cut the mounting hole for the unit taking care not to damage any pipes or mains cables 
beneath the mounting surface.

 

 

Cutout 

 

Void Depth

 

 

3. 

Fit  the  housing  into  position  and  secure. This  surround  may  be  cemented  in  position. 
Wait until the cement has set before continuing with the installation.

Existing  fittings  must  be  completely  removed  before  installation  of  a  new  product.  Before 
removing the existing fitting, caref ully note  the position  of each set  of wires

.

1. 

The product comes with a housing unit that must be fitted into the hole prior to any 
wiring taking place. 

4. 

Remove the terminal box cover and set
aside for refitting later. Having identified
the wiring from your existing fitting,
connect to the terminals as shown on right: 

 

 

 

 

5. 

Refit the  cover in place and refit the screws. 

the cable to suit and tighten the gland 

the IP rating of the product.

184mm x 62mm 

 

60mm

Insert and secure the Brick Light

outer casing.

STEP 2

STEP 3

Feed power cables through rubber grommet, 

  connect to the terminal block inside 

                    

Fix in place the clear lens and

metal outer frame using the

screws provided.

STEP 4

Switch on the power supply at the

ON

main fuse box and test fitting.

STEP 5

Adjust 

to maintain

Switch off the power supply at the

consumer unit or fuse box.

the fitting. Refer to Wiring below

NEUTRAL

 LIVE 

 

BLUE (N)

BROWN (L)

SUPPLY

LIGHT FITTING

Check  That

 

 You have correctly identified the wires.
 The connections are tight.
 No loose strands have been left out of the connection block.

 

 Refit the cover and secure the four screws.