AIR SUPPLY AND CONNECTIONS

Do not use oxygen, combustible gases, or bottled gases as a power source for this tool as
tool may explode, possibly causing injury. Keep the tool pointed away from yourself and
others when connecting air source.

FITTINGS:

Install a male plug on the tool which is free flowing and which will release air pressure from the tool when
disconnected from the supply source.

HOSES:

Air hoses should have a minimum of 150 p.s.i. (10.6 kg/cm

2

) working pressure rating or 150 percent of the

maximum pressure that could be produced in the air system. The supply hose should contain a fitting that will
provide "quick disconnecting" from the male plug on the tool.

SUPPLY SOURCE:

Use only clean regulated compressed air as a power source for this tool. NEVER USE OXYGEN,
COMBUSTIBLE GASES, OR BOTTLED GASES, AS A POWER SOURCE FOR THIS TOOL AS TOOL MAY
EXPLODE.

REGULATOR:

A pressure regulator with an operating pressure of 0 - 125 p.s.i. (0 - 8.79 kg/cm

2

) is required to control the

operating pressure for safe operation of this tool. Do not connect this tool to air pressure which can potentially
exceed 200 p.s.i. (14 kg/cm

2

) as tool may fracture or burst, possibly causing injury.

OPERATING PRESSURE:

Do not exceed recommended maximum operating pressure as tool wear will be greatly increased. The air
supply must be capable of maintaining the operating pressure at the tool. Pressure drops in the air supply can
reduce the tool's driving power. Refer to "TOOL SPECIFICATIONS" for setting the correct operating pressure
for the tool.

FILTER:

Dirt and water in the air supply are major causes of wear in pneumatic tools. A filter will help to get the best
performance and minimum wear from the tool. The filter must have adequate flow capacity for the specific
installation. The filter has to be kept clean to be effective in providing clean compressed air to the tool. Consult
the manufacturer's instructions on proper maintenance of your filter. A dirty and clogged filter will cause a
pressure drop which will reduce the tool's performance.

LUBRICATION

Frequent, but not excessive, lubrication is required for best performance. Oil added through the air line
connection will lubricate the internal parts. Do not use detergent oil or additives as these lubricants will cause
accelerated wear to the seals and bumpers in the tool, resulting in poor tool performance and frequent tool
maintenance.

If no airline lubricator is used, add oil during use into the air fitting on the tool once or twice a day. Only a few
drops of oil at a time is necessary. Too much oil will only collect inside the tool and will be noticeable in the
exhaust cycle.

COLD WEATHER OPERATION:

For cold weather operation, near and below freezing, the moisture in the air line may freeze and prevent tool
operation. We recommend the use permanent antifreeze (ethylene glycol) as a cold weather lubricant.

CAUTION: Do not store tools in a cold weather environment to prevent frost or ice formation on the
tools operating valves and mechanisms that could cause tool failure.

NOTE:Some commercial air line drying liquids are harmful to “O”-rings and seals – do not use these
low temperature air dryers without checking compatibility.

Содержание 208-5012

Страница 1: ...OPERATORS SHOULD STUDY THIS MANUAL TO UNDERSTAND AND FOLLOW THE SAFETY WARNINGS AND INSTRUCTIONS KEEP THESE INSTRUCTIONS WITH THE TOOL FOR FUTURE REFERENCE IF YOU HAVE ANY QUESTIONS CONTACT YOUR REPR...

Страница 2: ...the foregoing this limited warranty does not cover any damage that has resulted from abuse or misuse of the Merchandise This warranty 1 excludes expendable parts including but not limited to blades br...

Страница 3: ...d repair personnel Service or maintenance performed by unqualified personnel may result in a risk of injury When servicing a tool use only identical replacement parts Use of unauthorized parts may cre...

Страница 4: ...stance from the tool while tool is in operation as accidental actuation may occur possibly causing injury The operator must not hold the trigger pulled on contact arm tools except during fastening ope...

Страница 5: ...rrect operating pressure for the tool FILTER Dirt and water in the air supply are major causes of wear in pneumatic tools A filter will help to get the best performance and minimum wear from the tool...

Страница 6: ...LIGHT WEIGHT MAGNESIUM HOUSING The light weight magnesium housing helps reduce work fatigue TOOL FREE DRIVE DEPTH ADJUST The tool free depth adjust lets the operator select precise driving depth of t...

Страница 7: ...ontrol of the fastener drive depth from flush with the work surface to shallow or deep countersink First set the air pressure for consistent drive in the specific work Then use the depth adjustment to...

Страница 8: ...ver point the tool at anyone else Never engage in horseplay Never pull the trigger unless nose is directed at the work Always handle the tool with care Do not pull the trigger or depress the trip mech...

Страница 9: ...FASTENER PLACEMENT To operate the tool in this manner first position the contact trip on the work surface WITHOUT PULLING THE TRIGGER Depress the contact trip until the nose touches the work surface a...

Страница 10: ...MUST NOT CYCLE Release the trigger The trigger must return to the trigger stop on the frame C Pull the trigger and press the contact trip against the work surface THE TOOL MUST NOT CYCLE D With finger...

Страница 11: ...PROCEDURE FOR SEALS When repairing a tool make sure the internal parts are clean and lubricated Use a small amount of oil on all moving surfaces and pivots After reassembly add a few drops of oil thr...

Страница 12: ...e Air pressure too low Check air supply equipment Skipping fasteners intermittent feed Worn bumper Replace bumper Tar dirt in driver channel Disassemble and clean nose and driver Air restriction inade...

Отзывы: