PROBLEM:
Vacuum motor does not run.
POSSIBLE CAUSE:
POSSIBLE SOLUTION:
1. Broken or loose belt.
1. Replace or retighten belt.
2. Brush seized with nap or strings.
2. Clean bearings and brush of debris.
3. Motor failure.
6. Contact manufacturer or service center.
PROBLEM:
Loss of vacuum.
POSSIBLE CAUSE:
POSSIBLE SOLUTION:
1. Loose or broken fan.
1. Contact manufacturer or service center.
2. Motor failure.
2. Contact manufacturer or service center.
3. Broken housing.
3. Contact manufacturer or service center.
4. Full paper filter bag.
4. Replace filter bag.
PROBLEM:
Motor will not run.
POSSIBLE CAUSE:
POSSIBLE SOLUTION:
1. Broken switch.
1. Contact manufacturer or service center.
2. Damaged line cord.
2. Contact manufacturer or service center.
3. Damaged motor
3. Contact manufacturer or service center.
PROBLEM:
Dust blowing from vac when running.
POSSIBLE CAUSE:
POSSIBLE SOLUTION:
1. Full paper filter bag.
1. Replace paper filter bag.
2. Paper filter bag not installed or
2. Reinstall paper bag.
off adaptor.
3. Cloth filter bag dirty.
3. Clean cloth filter bag
PROBLEM:
High pitched whine.
POSSIBLE CAUSE:
POSSIBLE SOLUTION:
1. Loose belt.
1. Tighten belt.
2. Broken or chipped fan.
2. Contact manufacturer or service center.
T
ROUBLE
S
HOOTING
G
UIDE
PN 324272 Rev C - Wide Area Vacuum Manual - Printed in USA 07/16/07
Disconnect power before servicing vacuum.
Repairs should only be performed by an authorized service center.
C
AUTION
:
W
ARNING
:
P
AGE
12
Address:
777 South Street
Newburgh, N Y 12550-0606
TEL:
(800)835-7812
(845)565-8850
FAX:
(800)752-6883
(845)565-9392
URL:
www.mastercraftusa.com
E-Mail: