Installation

3

ELECTRICAL SPECIFICATIONS

INSTALLATION

See Fig. 1 for typical installation connections to pump
(

NOTE:

Fountain accessories not included with pump).

1. Install the pump on a hard level surface. Make sure

that the pump cannot pick up rocks, mud and debris,
etc. If necessary, put a block under the pump to raise
it slightly. If used with a fountain jet, position the
pump so that the fountain jet is above the surface of
the water.

2.

Protect the power cord from damage.

Uncovered

cords should be routinely inspected for damage or
deterioration. 

DO NOT

operate the pump if the cord

is damaged.

3. If used in a garden pond, adjust the diverter valve to

control the fountain spray height and flow over the
waterfall. 

Do not

restrict pump suction to adjust

flows. Restricting the suction will starve the pump for
water and can damage the pump.

4. If the pump is connected to a pond filter, adjust the

diverter valve to provide adequate flow to the filter.
Refer to the filter instruction manual to determine
flow requirements of filter.

CUSTOMER HOTLINE: 1-877-455-5508

PUMP CAPACITY

Motor

Minimum

Pumps

Motor

Full Load

Circuit

Down

H.P.

Amps

Req. (Amps)  

To

1/6

1.5

15

7/16” (11 mm)

3388 0399

Use foliage to cover
tubing to waterfall

Diverter
valve

Power
cord

GFCI
outlet

Raise the pump
off of the bottom
of the pond

Plastic
tubing
to waterfall

Landscaping
rocks

Figure 1: Typical garden pond and waterfall installation.

Head in feet

0

5

10

15

20

Head in metres

0

1.5

3

4.5

6.1

Litres/minute

76

63

43

25

0

Gallons/minute

20

17

11

7

0

MD

1" NPT to 
garden hose 
adaptor

Includes 
three
different 
adaptors

Pump includes the adaptors below.

1 1/4 x 1" NPT
adaptor

 1/2, 3/4, or
1", barbed
hose adaptor 

Figure 2: Typical installation setup.

Содержание 62-3558-8

Страница 1: ... MANUAL Submersible Pond Utility Pump PRINTED IN U S A 253P6060 1 23 03 62 3558 8 MD MD Installation Operation Parts For further operating installation or maintenance assistance Consumer Hotline 1 877 455 5508 ...

Страница 2: ...e servic ing any component 8 Drain all water from the system before servicing 9 Secure the discharge line before starting pump An unsecured discharge line will whip possibly causing personal injury and or property damage 10 Check hoses for weak or worn condition before each use making certain that all connections are secure 11 Periodically inspect the pump and system compo nents Keep the screen fr...

Страница 3: ...lows Restricting the suction will starve the pump for water and can damage the pump 4 If the pump is connected to a pond filter adjust the diverter valve to provide adequate flow to the filter Refer to the filter instruction manual to determine flow requirements of filter CUSTOMER HOTLINE 1 877 455 5508 PUMP CAPACITY Motor Minimum Pumps Motor Full Load Circuit Down H P Amps Req Amps To 1 6 1 5 15 ...

Страница 4: ...y the water flowing through the housing 4 This pump is designed to pump cold water only Pumping heated liquids can overheat the motor and cause the thermal overload to trip 5 Pump can run in water that doesn t completely cover the motor housing but the inlet must be completely submerged or it will break suction and will not move any water 6 Keep the inlet screen clean at all times If the bottom su...

Страница 5: ...ing caught in impeller Clean out impeller or replace pump Worn or defective parts or Clean impeller if plugged otherwise replace pump plugged impeller Check valve installed without Drill a 1 16 1 8 1 6 3 2 mm dia hole between pump discharge vent hole check valve Intermittent running Thermal overload tripped Protect the installation from the sun or pump stopped Pump cooler water automatically Check...

Страница 6: ...se accident misapplication tampering alteration nor due to improper installation operation maintenance or storage nor to other than normal application use or service including but not limited to operational failures caused by corrosion rust or other foreign materials in the system or operation at pres sures in excess of recommended maximums as set forth in the owner s manual Requests for service u...

Страница 7: ...ur étangs à usage général IMPRIMÉ AUX É U 253P6060 23 1 03 62 3558 8 MD MD Installation Fonctionnement Pièces Renseignements supplémentaires sur l utilisation l installation et l entretien de la pompe Assistance téléphonique 1 877 455 5508 ...

Страница 8: ...n 9 Bien immobiliser la canalisation de refoulement avant de faire fonctionner la pompe Une canalisation de refoule ment non immobilisée risque de se déplacer comme un fouet et de causer des blessures corporelles et des dom mages matériels 10 Avant chaque utilisation s assurer que les tuyaux souples ne comportent pas de points faibles ni de parties usées et que tous les raccords sont bien serrés 1...

Страница 9: ...ur de façon que le débit vers le filtre soit adéquat Se reporter au guide d utilisation livré avec le filtre pour déterminer le débit adéquat vers le filtre SERVICE D INFORMATION 1 877 455 5508 3388 0399 Use foliage to cover tubing to waterfall Diverter valve Power cord GFCI outlet Raise the pump off of the bottom of the pond Plastic tubing to waterfall Landscaping rocks Figure 1 Installation type...

Страница 10: ...froidie par l eau qui la traverse 4 Cette pompe est conçue pour ne pomper que de l eau froide Le pompage de liquides chauds risque de faire surchauffer le moteur et de causer le déclenchement du dispositif de protection contre les surcharges 5 La pompe peut fonctionner même si l eau ne couvre pas complètement le carter du moteur Toutefois la bouche d entrée doit toujours être complètement immergée...

Страница 11: ...rbine sont usées ou Nettoyer la turbine si elle est bouchée sinon remplacer la pompe défectueuses ou bien la turbine est bouchée Un clapet de non retour a été posé mais Percer un trou de 1 16 à 1 8 de pouce 1 6 à 3 2 mm de diamètre entre le un trou d aération n a pas été prévu tuyau de refoulement de la pompe et le clapet de non retour Fonctionnement Le dispositif de protection contre les Protéger...

Страница 12: ...retenue ou entreposée d une façon inadéquate de plus la garantie sera aussi nulle et non avenue si la pompe est utilisée contrairement aux possibilités d utilisation normales si elle fait défaut à la suite de la forma tion de corrosion ou de rouille de l infiltration de toute matière étrangère ou si elle est employée d une façon telle qu elle excède les limites maximales admissibles indiquées dans...

Отзывы: