MasterCraft 62-3523-0 Скачать руководство пользователя страница 2

Safety

2

For parts or assistance, call customer service at 

1-877-455-5508

Limited Warranty

Mastercraft warrants that the products specified in this warranty are free from defects in material or 
workmanship.

If within 

two (2) years

from the date of the original consumer purchase, this pump shall prove to be defec-

tive, it shall be repaired or replaced subject to the terms and conditions set forth below.

General Terms and Conditions

This warranty shall not apply to acts of God, nor shall it apply to products which have been subject to neg-
ligence, abuse, accident, misapplication, tampering, alteration; nor due to improper installation, operation,
maintenance or storage; nor to other than normal application, use or service, including but not limited to,
operational failures caused by corrosion, rust or other foreign materials in the system, or operation at pres-
sures in excess of recommended maximums as set forth in the owner’s manual. 

Requests for service under this warranty shall be made by returning the product to the retail outlet as soon
as possible after the discovery of any defect. We will subsequently take corrective action as promptly as rea-
sonably possible.

This warranty sets forth our sole obligation and the purchaser’s exclusive remedy for defective products.

DESCRIPTION

This submersible sump pump is designed for home
sumps. Unit is equipped with a 3-prong grounding-type
power cord. Ball bearings on motor shaft never need
lubrication. Automatic reset thermal protection.

SPECIFICATIONS

Power supply required ................................115 V, 60 Hz

Motor duty ....................................................continuous*

Liquid Temp. Range .................32° to 77° F (0° to 25° C) 

Individual Branch Circuit Required (minimum) ..10 Amps

Discharge Adapter: .......................................1 1/4" FNPT

*NOTICE:

For continuous operation, water depth must be

at least 5" (13 cm), to prevent motor from overheating.

NOTICE:

This unit is not designed for applications

involving salt water or brine! Use with salt water or
brine will void warranty.

Pump water only with this pump.

PERFORMANCE

ELECTRICAL & SWITCH
SPECIFICATIONS

GENERAL SAFETY INFORMATION

Electrically powered sump pumps normally give many
years of trouble-free service when correctly installed,
maintained, and used. However, unusual circumstances
(interruption of power to the pump, dirt/debris in the
sump, flooding that exceeds the pump’s capacity, electri-
cal or mechanical failure in the pump, etc.) may prevent
your pump from functioning normally. To prevent possible
water damage due to flooding, consult your retailer about
a secondary AC sump pump, a DC backup sump pump,
and/or a high water alarm. See the “Troubleshooting
Chart” in this manual for information about common
sump pump problems and remedies. For more informa-
tion, call customer service at 1-877-455-5508.

1. Know the pump application, limitations, and poten-

tial hazards.

2. Disconnect power before servicing.

3. Release all pressure within system before servicing

any component.

4. Drain all water from system before servicing.

5. Secure discharge line before starting pump. An unse-

cured discharge line will whip, possibly causing per-
sonal injury and/or property damage.

6. Check hoses for weak or worn condition before each

use, making certain that all connections are secure.

7. Periodically inspect sump, pump and system compo-

nents. Keep them free of debris and foreign objects.
Perform routine maintenance as required. 

8. Provide means of pressure relief for pumps whose

discharge line can be shut off or obstructed.

GPH (LPH) AT TOTAL FEET (M)

Motor

5

10

15

Series

HP

(1.5 m)

(3 m)

(4.5 m)

CAPACITY GALLONS(L)/HOUR

62-3523-0

4/10

2100

1700

925

18 Ft.

(7,949)

(6,435)

(3,501)

(5.5 M)

No flow 

at height

shown

below

Motor

Individual

*Switch Setting

Motor Full Load Branch Circuit

in inches (mm)

Series

HP

Amps

Req. (Amps)

On

Off

62-3523-0

4/10

3.0

10

11" (279) 5" (127)

Содержание 62-3523-0

Страница 1: ...llation Operation For further operating installation or maintenance assistance Call 1 877 455 5508 2004 PRINTED IN U S A 1000000944 Rev 8 12 04 MD 62 3523 0 MD OWNER S MANUAL CONTRACTOR Submersible Sump Pump ...

Страница 2: ...nt motor from overheating NOTICE This unit is not designed for applications involving salt water or brine Use with salt water or brine will void warranty Pump water only with this pump PERFORMANCE ELECTRICAL SWITCH SPECIFICATIONS GENERAL SAFETY INFORMATION Electrically powered sump pumps normally give many years of trouble free service when correctly installed maintained and used However unusual c...

Страница 3: ...f tile concrete steel or plastic Check local codes for approved materials and for proper installation 2 Install pump in pit so that switch operating mecha nism has maximum possible clearance 3 Pump should not be installed on clay earth or sand sur faces Clean sump pit of small stones and gravel which could clog pump Keep pump inlet screen clear NOTICE Do not use ordinary pipe joint compound on pla...

Страница 4: ...f obstructions or blockages of impeller cannot be cleaned out from the outside for instance by washing out with a garden hose replace pump Hazardous voltage can shock burn or kill Unplug pump before attempting to clean or work on pump TROUBLESHOOTING 5 127mm 3127 1297 NOTICE Do not change tether length of float switch Float must swing through its complete arc without interference Float Switch Teth...

Страница 5: ...t Renseignements supplémentaires sur l utilisation l installation et l entretien de la pompe Composez le 1 877 455 5508 2004 IMPRIMÉ AUX É U 1000000944 Rév 12 8 04 MD 62 3523 0 MD GUIDE D UTILISATION Pompe d assèchement immergée ...

Страница 6: ...ra vail d entretien ou de réparation 5 Fixez le boyau de refoulement avant de mettre la pompe en marche S il n est pas fixé en place il se déplacera comme un fouet et il risquera de causer des blessures per sonnelles et des dommages matériels 6 Inspectez les boyaux toutes les fois que vous avez l intention de vous en servir afin de repérer toute faiblesse ou tout signe d usure assurez vous que tou...

Страница 7: ...e plastique Consultez les codes locaux pour déterminer les matériaux approuvés et la méthode d installation adéquate 2 Installez la pompe dans la fosse de façon que le mécanisme actionnant l interrupteur ait le plus d espace libre possible 3 Ne placez jamais la pompe directement au sol sur de la terre de l argile ou du gravier Éliminez de la fosse les petites pierres et le gravier qui pourraient b...

Страница 8: ...r de la pompe elle sera détruite S il est impossible d enlever ce qui obstrue la turbine sans ouvrir le carter par exemple de la laver avec un boyau d arrosage remplacez la pompe Tension dangereuse risque de chocs électriques de brûlures et même de mort Débranchez la pompe avant d effectuer des travaux d entretien ou de réparation RECHERCHE DES PANNES 5 127mm 3127 1297 REMARQUE ne modifiez pas la ...

Отзывы: