Troubleshooting
5
CUSTOMER HOTLINE: 1-877-455-5508
SYMPTOM
POSSIBLE CAUSE(S)
CORRECTIVE ACTION
Pump won’t
Blown fuse or circuit breaker has tripped
If blown, replace with fuse of proper size or reset circuit breaker.
start or run
Low line voltage
If voltage under recommended minimum, check size of wiring from main
switch on property. If OK, contact power company or hydro authority.
Defective motor
Replace pump.
Pump operates but
Low line voltage
If voltage under recommended minimum, check size of wiring from main
delivers little or no
switch on property. If OK, contact power company or hydro authority.
water
Something caught in impeller
Replace pump.
Worn or defective parts
Replace pump.
Check valve installed without
Drill a 1/16–1/8" (1.6–3.2 mm) dia. hole between pump discharge.
vent hole
& check valve.
Intermittent running
Thermal overload has tripped
Protect the installation from the sun.
or pump stopped
Pump cooler water.
automatically
Pump has run dry; add water.
NOTICE:
This pump has no serviceable parts inside the
case. Opening the case will ruin the pump. For obstruc-
tions or blockages of the impeller, replace the pump.
Hazardous voltage; can shock, burn or kill.
Unplug the pump before attempting to clean or work on
the pump.