7
Amperage rating of the
tool (120 V circuit only)
Total length of the extension cord
25’
(7.6 m)
50’
(15.2 m)
100’
(30.4 m)
150’
(45.7 m)
More than
Not more
than
Minimum Gauge for the extension cord
(AWG)
0
6
18
16
16
14
6
10
18
16
14
12
10
12
16
16
14
12
12
16
14
12
Not recommended
WARNING:
Ensure that the power-supply outlet in question is properly
grounded. If you are not sure, have a licensed electrician check the outlet.
WARNING:
Use proper circuit protection to avoid electrical hazards, fire
hazards, or damage to the tool.
SPECIFIC SAFETY RULES
Use only crosscutting saw blades.
When using the mitre saw to cut
nonferrous metal, make sure the blade has a negative hook angle.
IMPORTANT: Do not use thin-kerf blades.
Thin-kerf blades can deflect and
contact the guard, which may cause injury to the operator.
Do not
operate the Mitre Saw until it is completely assembled and installed
according to these instructions.
If not
thoroughly familiar with the operation of mitre saws, seek guidance
from a supervisor, instructor, or other qualified person.
Always
hold the workpiece firmly against the fence and table. Do not perform
any operation freehand. Use a clamp or vise whenever possible
Keep hands
out of the path of the saw blade. If holding the workpiece causes
the hands to be within the “No-Hands” zone (3’’ (7.6 cm) away from the
blade), the workpiece should be clamped in place before making the cut.
Be sure
the blade is sharp, runs freely, and is free of vibrations.
Allow
the motor to come to full speed before starting a cut.
Keep the motor’s air slots clean
and free of chips or dust.
Always make sure
all adjusting knobs are tightened before cutting, even if the
table is positioned in one of the positive stops.