MasterCraft 52-0052-2 Скачать руководство пользователя страница 3

Before  operating  your  multimeter,  become  familiar  with  each  control.  A 

clear  understanding  of  how  your  multimeter  works  will  help  to  avoid 

mistakes and minimize measurement errors, instrument damage and the 

possibility of injury. 

 

SAFETY INSTRUCTIONS

 

This meter has been designed for safe use, depending on UL61010-1, but 
must  be  operated  with  caution.  The  rules  listed  below  must  be  carefully 
followed for safe operation.

 

(1) NEVER operate this device when the back cover is open or not properly 

attached in its place.

 

(2) Make sure that the insulation of leads is not damaged.

 

(3) When “BAT”appears on the display, change both batteries for the accuracy 

of measurement.

 

(4) NEVER apply voltage to the meter that exceeds the specified maximum:

 

DC1000 or AC 750V.

 

(5) USE extreme caution when working with voltage over the 36V safe point.

 

(6) NEVER change the position of the function switch during measuring.

 

(7) CHOOSING the right positions of all function switches before testing.

 

(8) NEVER change any connection on the circuit board of the meter.

 

(9) USE only damp cloth or mild detergent to clean the outside of the meter.

 

(10) Safety Symbols:

 

Hazardous voltage  

Read the manual first  

Connect to common ground

 

 

This  product  is  protected  by  DOUBLE  INSULATION.  Service  of  this 

multimeter by a professional person only. Otherwise it could hamper 

the safe operation and severe injury or even death may result.

 

The following section, in conjunction with Fig.1, will describe the proper functions of your 

multimeter.

 

1. LCD

 

3 3/4 digit

 

 

2. Function/Range switch

 

Use to select the desired measurement or "OFF" position.

 

 

3. 10 A Jack

 

Plug-in connection for red (positive) test lead for DC 10 A measurements only.

 

 

4. mA/

µ

A Jack

 

Plug-in connection for red (positive) test lead for current measurements up to

 

400 mA only.

 

Содержание 52-0052-2

Страница 1: ...MANUAL WARNING READ AND UNDERSTAND THIS MANUAL BEFORE USING YOUR MULTIMETER FAILURE TO UNDERSTAND AND COMPLY WITH WARNINGS AND OPERATING INSTRUCTIONS CAN RESULT IN SERIOUS OR FATAL INJURIES AND OR PRO...

Страница 2: ...raft 7 9 Hz Range Relative 10 8 Data Hold Backlight NPN PNP AUTO POWER OFF OFF E E C C E E OHM hFE AC DC 3 10A A mA TEMP A AUTO RANGING SELECTION AUTOMATIQUE FUSED 400mA MAX 6 V F CAP CAT II 1000V DC...

Страница 3: ...with voltage over the 36V safe point 6 NEVER change the position of the function switch during measuring 7 CHOOSING the right positions of all function switches before testing 8 NEVER change any conne...

Страница 4: ...en first turned ON the multimeter goes into auto ranging and the word AUTO will appear in the upper left corner of the display When this button is pressed a manual range is selected and the AUTO will...

Страница 5: ...CD press this button once to cancel 9 AC DC Hz Button In the OHM mode use this button to choose between continuity check or diode test or resistance test In the A AC and D DC mode use this button to c...

Страница 6: ...rom last use Low battery indication the battery symbol is displayed if battery voltage drops below operating voltage Operating environment 5 35 C humidity 75 Storing environment 10 50 C humidity 75 Po...

Страница 7: ...00 A 100 nA 1 2 rdg 8 dgts 4000 A 1 A 40 mA 10 A 400 mA 100 A 10 A 10 mA 3 rdg 5 dgts RESISTANCE Range Resolution Accuracy 400 100 m 0 8 rdg 5 dgts 4 K 1 40 K 10 400 K 100 4 M 1 K 40 M 10 K 1 2 rdg 10...

Страница 8: ...forward voltage test current of 1 mA maximum Continuity check audible signal will sound if the resistance is less than 30 Transistor test reads approximate hFE value of transistor under test Understa...

Страница 9: ...when working with high voltage Never connect test leads with circuit when changing the position of function switch DC Current Measurement AC DC 1 Set the function range switch to the AC DC position an...

Страница 10: ...6 function switch Do not make current measurements on the 10 A scale for longer than 15 seconds every 30 minutes Exceeding 15 seconds may cause damage to the multimeter and or test leads...

Страница 11: ...function range switch to the OHM position 2 Insert the black negative test lead into the COM jack and the red positive test lead into the V F jack 3 Press the button until OL and M appear on the LCD 4...

Страница 12: ...from the rest of the circuit CAUTION Never measure a device that has voltage on it Capacitance Measurement 1 Discharge the capacitor being tested before starting the measurment 2 Set the function rang...

Страница 13: ...Touch the temperature probe head to the part whose temperature you wish to measure Keep the probe touching the part under test until the reading stabilizes about 30 seconds 4 Read the temperature on...

Страница 14: ...move old battery and insert a new one Replace the back cover and tighten screw Dispose of old battery properly Changing Fuses 500 mA 250 V Turn the multimeter to the OFF position and disconnect the te...

Отзывы: