GENERAL USE

• 

Pump only clean water with your pump. To avoid clogging the pump and damaging the 
shaft seal, do not pump water containing solids, foreign material, sand, silt, or abrasives.

• 

If you are boosting the pressure from a well pump, be sure that the system check valves 
are tight. If the system pressure drops when the well pump is not running, the pump 
may start and cycle. Excessive or rapid cycling may damage the motor and will void the 
warranty.

• 

Do not use pipe joint compound on pump ports; use only PTFE tape to seal the threads. 
Pipe joint compound will damage the controller materials.

• 

Tighten all the piping joints to the pump hand tight plus 1 1/2 turns (not more). 
Overtightening may break the pump and will void the warranty.

• 

Pipe and fittings to the pump should be at least nominal 1” (2.5 cm) diameter. Pipe or 
fittings less than 1” (2.5 cm) in diameter will reduce performance and may damage the 
pump through cavitation.

• 

Make sure that there are no air leaks or air pockets in the suction pipe. An air leak in the 
suction pipe may draw air in, although no water leaks out. Air leaks and air pockets will 
prevent the pump from priming properly, and can substantially reduce its performance.

• 

The pump mount should be level, solid, as near as possible to the water source, and 
protected against excess moisture and flooding.

• 

Use the shortest possible run for piping and the smallest possible number of fittings. Long 
pipe runs and numerous fittings increase friction and reduce the flow of water.

• 

Support the weight of the piping and pump.

• 

Do not allow the pump, pressure controller, or any system components to freeze. Freezing 
will damage the pump and void the warranty.

• 

Periodically inspect the pump, pressure controller, and system components.

CAUTION!

•   Risk of leaks and flooding. Do not use this pump with inlet pressure less than 10 PSI (70 kPa) or 

greater than 50 PSI (345 kPa).

WARNING!

•   Pressure hazard and risk of explosion. This pump can develop high pressure when operated with 

the discharge shut off or obstructed. For safe operation, we recommend the following:

      If not already in the plumbing system, install a pressure relief valve in the pump discharge line 

capable of passing the full pump flow at 100 PSI (689 kPa). If local code requires installation of a 
pressure relief valve capable of handling the full pump flow at a pressure less than 100 PSI (689 
kPa), follow the code requirements. Run the relief valve discharge to a floor drain or other drain 
that will give adequate runoff.

NOTE:

 

The priming plug has an O-ring already installed and does not require sealing.
Local code may require a pressure relief valve or pressure regulator.

Содержание 062-3593-2

Страница 1: ...s IMPORTANT Please read this manual carefully before running this jet pump and save it for reference INSTRUCTION MANUAL SHALLOW WELL JET PUMP WITH ELECTRONIC PRESSURE CONTROL 9 Model No 062 3593 2 ...

Страница 2: ...headline bars continuation tabs notes warnings headline bars continuation tabs notes warnings ...

Страница 3: ...is manual contains important safety and operating instructions Read all instructions and follow them with use of this product TABLE OF CONTENTS Quick Start Guide 4 Technical Specifications 6 Safety Guidelines 8 Important Information 11 Key Parts Diagram 12 Assembly Instructions 13 Operating Instructions 17 Troubleshooting 18 Warranty 19 TABLE OF CONTENTS ...

Страница 4: ...s model no 062 3593 2 contact us 1 800 689 9928 4 QUICK START GUIDE Prime the pump 2 Connect the pump outlet to the water system in your house Plug the pump into 115 V GFCI outlet 3 Connect the suction pipe to the pump inlet 1 Max 25 7 6 m Foot valve Check valve Pipe SHALLOW WELL INSTALLATION ...

Страница 5: ... 115 V GFCI outlet 1 Typical bypass piping needed to allow removal of pump for repair without shutting down household water system Turn on the ball valve in the main water supply line and close the two ball valves in both the pump outlet and inlet 2 Unions To household pump discharge Grounded GFCI protected 115 V outlet Water supply in pump suction Check valve TYPICAL HOUSEHOLD BOOSTER INSTALLATIO...

Страница 6: ... bearing Ball bearing Lower bearing Ball bearing Single phase Permanent split capacitor PSC Motor protection Auto reset thermal overload protection in motor Construction material Aluminum alloy for motor house plastic for diffuser and impeller stainless steel for pump body Motor NEMA L torque curve squirrel cage induction class B insulation MOTOR AND ELECTRICAL SKU number 062 3593 2 HP 3 4 Volt 11...

Страница 7: ...m 15 4 6 m 20 6 m 25 7 6 m Gallons per hour Litres per hour 600 2271 564 2135 528 1999 480 1817 408 1544 324 1226 17 1 16 43 4 cm 10 11 16 27 1 cm 15 3 8 39 1 cm 7 1 4 18 4 cm 8 15 16 22 7 cm 5 5 16 13 5 cm 8 13 16 22 4 cm 3 13 16 9 7 cm All performances shown at 30 PSI discharge pressure ...

Страница 8: ...rticularly the Canadian Electrical Code and local codes and ordinances Disconnect the power supply to the pump drain all water and release all pressure from the water system before servicing any pump component Risk of fire or explosion Do not pump flammable or explosive liquids such as oil gasoline kerosene ethanol etc Do not use in the presence of flammable or explosive vapours Using this pump wi...

Страница 9: ...A single leak will prevent the proper operation of the pump Wrap thread tape clockwise on all threaded connections For all non threaded connections you must use PVC Purple Primer and PVC Cement to ensure airtight seals Measure all pipe lengths before attaching A foot valve is a check valve that is used to keep the water from running back into the well from the pump and maintain hydraulic pressure ...

Страница 10: ...the numbers on the pump s identification plate and record at the end of the manual for future reference INSULATION TEST Before the pump is put into service an insulation megger test should be performed on it The ohm values as well as the volts and amps should be recorded PUMP TEST After the pump has been properly wired and primed it is advisable to check the system by filling with liquid and allow...

Страница 11: ...ount should be level solid as near as possible to the water source and protected against excess moisture and flooding Use the shortest possible run for piping and the smallest possible number of fittings Long pipe runs and numerous fittings increase friction and reduce the flow of water Support the weight of the piping and pump Do not allow the pump pressure controller or any system components to ...

Страница 12: ... 3593 2 contact us 1 800 689 9928 12 PARTS LIST No Description Qty 1 Connector 1 2 Electronic control 1 3 Power cord 1 4 Plug 1 5 Priming elbow No Description Qty 6 Pressure gauge 1 7 Pump body 1 8 Connection wire 1 9 Motor 1 1 2 4 5 7 6 3 8 9 KEY PARTS DIAGRAM ...

Страница 13: ... be at least 10 3 m below the well s water level while the pump is running in order to prevent the pump from sucking air due to water level drawdown LOCATION OF THE PUMP Decide on the area for the pump installation Select a pump location with adequate space for future pump maintenance It can be located in the basement or utility room of the house at the well or between the house and the well If in...

Страница 14: ...water pressure is relieved close the faucet 6 READ STEP 6 COMPLETELY BEFORE STARTING WORK You must remove a length of pipe from the main water supply line to allow installation of tees for the pump The locations of the cuts must take into consideration the size of the tees being used the length of the threads in threaded joints or the overlap in glued or soldered joints etc Position the tees in li...

Страница 15: ... in the pump for the first time When you plug in the power cord the pump will start and run for a few seconds 14 When the pump stops running after it shuts off automatically the system is at the boosted pressures Inspect the pipe and fittings again for water leaks If any leaks appear unplug the pump turn the water main valve off open a faucet to relieve the pressure and repair the leak Repeat this...

Страница 16: ... Run dry operation Frequent starts caused by small water losses in the system Pressure drop The automatic pressure controller features the following LEDs and controls Power on LED indicates that the unit is electrically connected and that voltage is present The pump is ready to operate Pump on LED indicates that the pump is running and actually pumping water Restart button resets any safeties whic...

Страница 17: ...on LED should light up The Failure LED should go off If flow is adequate the pump will operate until several seconds after it reaches the set point pressure and the flow stops Lubrication The motor is lubricated at the factory for the life of the bearings The pump seal is water cooled and self lubricating NORMAL OPERATION OF THE PUMP Fill the pump with water before starting it Make sure that the p...

Страница 18: ...then open faucets and see if water is flowing through system Improper priming Clogged water filter Discharge valve closed Pipe size too small Impeller is plugged Pipes are frozen Re prime according to instructions Stop pump shut off water and change filter cartridge Filter should be installed on discharge side of pump Open valve Re pipe using pipe of the same size as suction and discharge ports on...

Страница 19: ...nts e this warranty will not apply where damage is caused by repairs made or attempted by others i e persons not authorized by the manufacturer f this warranty will not apply to any product that was sold to the original purchaser as a reconditioned or refurbished product unless otherwise specified in writing g this warranty will not apply to any product or part thereof if any part from another man...