model no. 062-3429-6 | contact us 1-800-689-9928
6
SAFETY
• Once the thermal protector detects that the pump has cooled to a safe
temperature, it will allow the pump to operate normally. If the pump is plugged
in, it may restart unexpectedly.
ADDITIONAL SAFETY PRECAUTIONS
1. Know the pump applications, limitations, and potential hazards.
2. Make certain the electrical power source is adequate for the requirements of
the pump.
3. ALWAYS disconnect the power to the pump before servicing.
4. Release all pressure (drain all water) within system before servicing any
component.
5. Secure discharge line before starting pump. An unsecured discharge line will
whip, possibly causing personal injury and/or property damage.
6. Secure the pump on a solid base to keep the pump vertical and above mud
and sand during operation to maximize pumping efficiency and prevent
clogging and premature pump failure.
7. Check that all pipe connections are tight to minimize leaks.
8. Connect the pump DIRECTLY to a grounded, GFCI outlet.
9. Extension cords may not deliver sufficient voltage to the pump motor.
Extension cords present a life threatening safety hazard if the insulation
becomes damaged or the connection ends fall into water.
10. Make certain the electrical circuit to the pump is protected by a 15 A or larger
fuse or circuit breaker.
11. Periodically inspect the pump and system components to be sure the pump
inlets are free of mud, sand, and debris. DISCONNECT THE PUMP FROM THE
POWER SUPPLY BEFORE INSPECTING.
12. Wear safety glasses at all times when working with pumps.
13. Follow all electrical and safety codes, particularly the National Electrical Code
(NEC) or the Canadian Electrical Code (CEC), and in the workplace, the
Occupational Safety and Health Act (OSHA) or the Canadian Centre for
Occupational Health and Safety (CCOHS).
14. This unit is designed only for use on 115 V (single phase), 60 Hz, and is
equipped with an approved 3-conductor cord and 3-prong grounded plug. DO
NOT REMOVE THE GROUND PIN UNDER ANY CIRCUMSTANCES. The 3-prong
plug must be directly inserted into a properly installed and grounded 3-prong,
grounding-type receptacle. Do not use this pump with a 2-prong wall outlet.
Replace the 2-prong outlet with a properly grounded 3-prong receptacle (a
GFCI outlet) installed in accordance with the NEC or CEC and local codes and
ordinances. All wiring should be performed by a qualified electrician.
15. Protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals.
Avoid kinking the cord. Do not use damaged or worn cords.