MasterCraft 062-3413-2 Скачать руководство пользователя страница 10

model no. 062-3413-2  |  contact us 1-800-689-9928

OPERATION INSTRUCTIONS

2

3

Storing the Pump:

Protect against flooding and 
excessive moisture by storing in a 
dry place.

Draining the Pump for Winter: 

a. Disconnect the suction (1) and 

discharge (2) lines from the 
pump (A).

b. Remove the water drain plug (3) 

from the pump (A).

c. Drain all piping below the frost 

line or store the piping indoors.

d. Store the pump indoors.

Running the Pump

Plug the power cord into a GFCI-protected  
electrical outlet and press the power switch 
to the On position. If the pump does not 
pump water within 2 minutes, turn the pump 

(A) off. Refill with clean water and make sure 

all connections are airtight. To turn the pump 
off, press the power switch to the off 
position.

DANGER: Risk of electric shock. Always 

disconnect the electrical supply before 
attempting to install, service, or perform any 
maintenance. If the power source is out of 

sight, lock and tag in the open (off) position 

to prevent unexpected power application. 
Failure to do so could result in fatal electrical 

shock. Only qualified electricians should 

repair this unit. Improper repair could result 

in fatal electric shock.

WARNING: Let the pump cool for at least 20 
minutes before attempting to service. The 
motor may be extremely hot. Personal injury 
may result.

10

A

A

1

2

3

Содержание 062-3413-2

Страница 1: ...INSTRUCTION MANUAL Stainless Steel IRRIGATION AND LAWN SPRINKLER PUMP IMPORTANT Please read this manual carefully before running this pump and save it for reference model no 062 3413 2 ...

Страница 2: ...2 ...

Страница 3: ...12 Warranty 13 TABLE OF CONTENTS TABLE OF CONTENTS 3 NOTE If any parts are missing or damaged or if you have any questions please call our toll free helpline at 1 800 689 9928 SAVE THESE INSTRUCTIONS This manual contains important safety and operating instructions Read all instructions and follow them with use of this product ...

Страница 4: ... 10 A Maximum flow 1200 U S GPH 4542 L h Discharge size 1 2 5 cm female national pipe thread FNPT 1 9 cm garden hose adaptor included Power cord length 6 7 2 m TECHNICAL SPECIFICATIONS 0 0 m 50 15 2 m 100 30 5 m 150 45 7 m 1200 U S GPH 4542 L h 900 U S GPH 3407 L h 480 U S GPH 1817 L h 40 U S GPH 151 L h PERFORMANCE TECHNICAL SPECIFICATIONS 4 ...

Страница 5: ...isassembling may cause dangerous electrical wiring issues CAUTION This pump is made of high strength corrosion resistant materials It will provide trouble free service for many years when properly installed maintained and used However inadequate electrical power or blockage by dirt could cause damage to the pump and void the warranty To minimize the potential for water damage due to pump failure p...

Страница 6: ... the connection ends fall into the water If using a 50 15 m cord use 16 gauge wire If using a 100 30 m cord use 14 gauge wire 10 Make certain the electrical circuit to the pump is protected by a 10 A or larger fuse or circuit breaker 11 Periodically inspect pump and system components to ensure that the pump inlets are free of mud sand and debris DISCONNECT THE PUMP FROM THE POWER SUPPLY BEFORE INS...

Страница 7: ...ions must be airtight A single leak will prevent proper operation of the pump and may cause the pump to run dry If the pump runs dry this will void the warranty WARNING Always use the handle to lift pump Never use a power cord to lift pump To avoid skin burns unplug and allow time for the pump to cool after periods of extended use Before beginning assembly of the product make sure all parts are pr...

Страница 8: ...d with 1 2 5 cm PVC pipe Note If you are using a PVC pipe you will need a 1 2 5 cm male NPT X slip adaptor Notice The inlet hose must be a reinforced type when pumping from lakes ponds or small streams A regular garden hose will collapse and lead to pump failure Note A foot valve MUST be used to maintain prime during operation Foot valves are sold separately b Connect an outlet pipe or 3 4 1 9 cm ...

Страница 9: ...is not designed to be used with under ground pop up sprinklers zoned systems If you have this type of system purchase a higher capacity lawn or irrigation pump Usage You can install a 100 pressure gauge sold separately on top of the discharge tee cap in order to monitor pressure WARNING Do not run the pump with the outlet pipe or hose nozzle closed This will cause damage to the pump or burst the h...

Страница 10: ... not pump water within 2 minutes turn the pump A off Refill with clean water and make sure all connections are airtight To turn the pump off press the power switch to the off position DANGER Risk of electric shock Always disconnect the electrical supply before attempting to install service or perform any maintenance If the power source is out of sight lock and tag in the open off position to preven...

Страница 11: ...tage is less than 108 V check the wiring size or use a shorter extension cord 3 Use a minimum 3 4 1 9 cm heavy duty garden hose 4 Use as short a hose as possible maximum of 50 15 m 1 The seal is worn 2 The shaft is grooved 3 The pump head is loose on the motor The seal leaks 1 Replace the seal Call for replacements 2 Replace the rotor Call for replacements 3 Ensure the pump is assembled properly a...

Страница 12: ... Seal holder 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Quantity 2 2 2 1 2 8 2 2 1 1 1 1 1 1 1 1 1 1 1 No Description Pump support Terminal box Power switch Sealing ring for terminal Cover Capacitor 40Mf 250V Bolt M4 8 Cord clip Power cord Cable holder Ball bearing 6202 Zz Z2 Shaft key A4 10 Rotor Motor stator End plate Bolt M5 138 Fan Fan cover 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35...

Страница 13: ...WARRANTY AND CAUSE DAMAGE OR PERSONAL INJURY This Mastercraft product carries a three 3 year LIMITED warranty against defects in workmanship and materials This product is not guaranteed against wear or breakage due to misuse and or abuse Made in China Imported by Mastercraft Canada Toronto Canada M4S 2B8 ...