TROUBLESHOO
TING
21
AIR
-
POWERED SIPHON
-
FEED SPRAY GUN 058
-
9336
-
2
Excessive overspray
1. Atomization pressure is too high.
2. Work surface is too far.
3. Improper stroking (arcing, gun
motion too fast).
1. Reduce pressure.
2. Adjust to proper distance.
3. Move at moderate pace, parallel to work
surface.
No spray
1. No pressure in gun.
2. Fluid control is not properly
opened.
3. Fluid is too heavy.
1. Check air lines.
2. Open fluid control.
3. Thin fluid or change to pressure feed system.
PROBLEM
POSSIBLE CAUSES
SOLUTIONS