MasterCraft 058-7936-6 Скачать руководство пользователя страница 9

MAINTENANCE 

   

To avoid personal injury, always shut off and unplug the unit and relieve all 

air pressure from the system before performing any service on the air compressor. 

 

Regular maintenance will ensure trouble-free operation. The items listed in the chart should be inspected on 

a regular basis. 

 

ITEM DESCRIPTION/REASON 

SERVICE 

INTERVAL 

Drain the tank. 

Through normal operation of your air compressor, 

condensation water will accumulate in the tank.  To 

prevent corrosion of the tank from the inside, 

condensation must be drained at the end of every 

workday. Be sure to wear protective goggles. Relieve 

the air pressure in the system and open the drain valve 

on the bottom of the tank to drain.    In cold conditions, it 

is especially important to drain the tank after each use 

to reduce the chance of problems resulting from the 

freezing of condensation water.

 

Daily 

Check the relief valve. 

Pull/activate the relief valve daily to ensure that it is 

operating properly and to clear the valve of any possible 

obstructions. 

Daily 

Clean the air filter. 

A dirty air filter will reduce air compressor performance 

and life. 

To avoid any contamination of the inside pump, the filter 

should be cleaned frequently and replaced on a regular 

basis. Foam filters should be cleaned in warm and 

soapy water. 

Weekly 

Test for leakages. 

Check that all connections are tight. Small leaks in any 

of the tank, hoses, connections or transfer tubes will 

substantially reduce the air compressor and tool 

performance. 

Spray a small amount of soapy water around the area of 

suspected leaks with a spray bottle. If bubbles appear, 

repair, replace or re-seal the faulty component. Do not 

over tighten any connections. 

Monthly 

Storage. 

Before storing the unit for a long period, use an air blow 

gun to clean all dust and debris from the air compressor. 

Disconnect and coil the power cord up. Clean the filter 

element and filter housing. Drain all moisture from the 

tank. Pull the pressure relief valve to release all 

pressure from the tank. Cover the entire unit to protect it 

from moisture and dust. 

N/A 

 

- 9 - 

Содержание 058-7936-6

Страница 1: ...rts Missing or Damaged Questions Toll Free Help Line 1 800 689 9928 IMPORTANT Ensure that all users have read all safety rules and operating instructions carefully before using this product Keep this...

Страница 2: ...UBLESHOOTING CHART 10 11 PARTS SCHEMATIC 12 PARTS LIST 12 WARRANTY 13 SPECIFICATIONSSPECIFICATION PRODUCT NUMBER 058 7936 6 PUMP 1 3 peak HP direct drive oil less PEAK HORSEPOWER 1 3 HP MOTOR 3900 RMP...

Страница 3: ...s could cause serious injury 5 RISK OF BURSTING Check the maximum pressure rating in the manual or the serial number label The compressor outlet pressure must be regulated so that it does not exceed t...

Страница 4: ...A ELECTRIC MOTOR AIR COMPRESSOR PUMP not visible B ON OFF SWITCH C AIR LINE OULET D REGULATED PRESSURE GAUGE E TANK PRESSURE GAUGE F AIR PRESSURE REGULATOR G PRESSURE RELIEF VALVE H AIR TANK I AIR TA...

Страница 5: ...ndard Equipment 1 25 recoil hose with NPT male fitting on both ends 2 Teflon Tape 3 Blow Gun 4 Blow gun adaptor 5 Tapered inflation nozzle 6 Inflation needle 7 Ball style tire inflation chuck 8 NPT fe...

Страница 6: ...4 mm NPT air hose D REGULATED PRESSURE GAUGE Display the current line pressure It is regulated by the regulator knobs E TANK PRESSURE GAUGE Indicates tank pressure in PSI F AIR PRESSURE REGULATOR A co...

Страница 7: ...the use of extension cords whenever possible If an extension cord must be used it must have a minimum wire size of 12 AWG and must be no longer than 50 15 m Use only a 3 wire extension cord that has a...

Страница 8: ...kwise to reach the desired pressure Do not exceed operating pressure of the tool or accessory being used 4 If a pressure regulator is present on your air compressor adjust it to the working pressure o...

Страница 9: ...ure that it is operating properly and to clear the valve of any possible obstructions Daily Clean the air filter A dirty air filter will reduce air compressor performance and life To avoid any contami...

Страница 10: ...essure of pressure tank Check valve is stuck open Remove and clean or replace Electrical connections are loose Contact authorized service centre or store Compressor motor will not run or start Possibl...

Страница 11: ...ugged into an extension cord Remove extension cord Tip It is better to use a longer hose instead of an extension cord Thermal overload protector cuts out repeatedly Dirt covered cooling surfaces Allow...

Страница 12: ...lt 4 4 Circuit Board 1 19 Cushion Pad 1 5 Washer 2 20 Fan 1 6 Bolt 2 21 Transfer Tube 1 7 Fuse 1 22 Nut M10x1 2 8 Pressure Switch 1 23 Brass Nipple 2 9 Bolt 1 24 Motor Assembly 1 10 Brass Nipple 1 25...

Страница 13: ...ups or adjustments e this warranty will not apply where damage is caused by repairs made or attempted by others i e persons not authorized by the manufacturer f this warranty will not apply to any pro...