NOTE:
The meter has a process of initialization before it enters
non-contact AC voltage detection mode. During this process,
the meter will not respond if you press the "
SELECT
" key. Only
after the process finishes (the display shows " " and the
built-in buzzer does not sound) can you press the "
SELECT
"
key to change meter function.
Instruction for the "SELECT" Key
Press and hold down the "
SELECT
" key for about 3 secs to turn on
the meter. The meter enters Auto Check mode.
In Auto Check mode, press the "
SELECT
" key to step through the
functions:
Auto Check mode (default)
→
continuity test
→
non-contact AC voltage detection
→
AC voltage measurement
→
DC voltage measurement
→
resistance measurement
→
frequency measurement
→
capacitance measurement
→
Auto Check mode.
Pressing and holding down the "
SELECT
" key for about 3 secs will
turn off the meter.
OPERATING INSTRUCTIONS
model no. 052-0726-0 | contact us 1-800-689-9928