GENERAL SAFETY INFORMATION

WARNING:

This heater requires hardwire installation (no plug). The installation of this product must 
be carried out by a certified electrician in accordance with all applicable local and national 
electrical codes.

Read and understand all installation and operation instructions prior to operating this unit. 
Observe all safety instructions.

Improper installation or failure to follow the procedures outlined in this instruction manual 
can result in serious electric shock.

NOTE: 

Compatible with a 240 V line voltage single pole wall thermostat. This thermostat must be 

installed by a certified electrician.

GENERAL SAFETY INFORMATION

1.  Use only copper wires rated for at least 75ºC.
2.  Heater airflow must be directed parallel to or away from adjacent wall.
3.  Observe wall, floor and ceiling clearance requirements.
4.  All wiring must be done according to applicable national and local electrical codes in 

the United States and Canada. The heater must be grounded as a precaution against 
possible electric shock. Heater circuit must be protected with proper fuses.

5.  The mounting and anchoring hardware must be capable of reliably supporting the 

weight of the heater and its mounting bracket.

6.  All electrical power must be disconnected and the main service box must be locked 

before inspecting cleaning or servicing the heater. This precaution must be followed 
to prevent serious electric shock.

7.  This heater is not suitable for use in hazardous locations as defined by the National 

Fire Protection Association (NFPA) in the United States. This heater has hot and 
arcing sparking parts inside. Do not use it in areas where gasoline paint or 
flammable liquids are used or stored.

8.  This heater is not suitable for use in corrosive atmospheres such as marine 

greenhouses or chemical storage areas.

9.  This heater must be mounted at least 8' (2.44 m) above the floor.

Содержание 043-5120-2

Страница 1: ...INSTRUCTION MANUAL GARAGE HEATER with Remote IMPORTANT Please read this manual carefully before running this garage heater and save it for reference model no EH 4604BY...

Страница 2: ...model no 043 5120 2 contact us 1 800 689 9928 2...

Страница 3: ...d Maintenance Warranty TABLE OF CONTENTS TABLE OF CONTENTS NOTE If any parts are missing or damaged or if you have any questions please call our toll free helpline at 1 800 689 9928 SAVE THESE INSTRUC...

Страница 4: ...pen close open open open Remote control C F 4 Model Number EH 4604BY Voltage 240 V Rated Power 5 000 W 7 500 W AMPS 20 9 31 3 TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS DESCRIPTION Electric uti...

Страница 5: ...by a reputable electrician before reusing 6 Do not use outdoors 7 This heater is not intended for use in bathrooms laundry areas and similar indoor locations Never locate heater where it may fall int...

Страница 6: ...earance requirements 4 All wiring must be done according to applicable national and local electrical codes in the United States and Canada The heater must be grounded as a precaution against possible...

Страница 7: ...f each heater supports the airflow of the others to provide best circulation of warm air as indicated in Figure 2 FRONT VIEW Note Minimum clearance to ceiling when not using mounting brackets is 1 5 8...

Страница 8: ...bracket screws with a wrench and slipping the handle off over the screw heads 3 Place a washer on screws before inserting through the holes in the mounting bracket and screw them securely into a ceil...

Страница 9: ...so they cannot be completely closed Do not attempt to defeat this feature damage to the unit can result Figure 5 Figure 6 ADJUSTING AIRFLOW DIRECTION 1 To turn the unit when it has been installed with...

Страница 10: ...Element 1250W Element 1250W Element 1250W Element 1250W Element 1250W Element Motor HL YJF10 240V 60Hz Temperature sensor Overheat OFF FAN LOW 5 000W HIGH 7 500W Watts Relay J2 Relay J3 Relay J1 close...

Страница 11: ...wire to the power block located in the base of the heater Figure 9 4 Turn on the power at the main electrical panel NOTE All wiring must be carried out by a certified electrician and must be in accor...

Страница 12: ...ing button to select the desired mode following this sequence Off Fan only Low mode 5 000 W High mode 7 500 W Press and hold Heater button for 5 seconds to switch between C and F temperature display P...

Страница 13: ...ON again and the red indicator will turn off when the unit cools down to normal levels Should the unit overheat and cause the thermal cut out to engage again the cause of the overheating must be deter...

Страница 14: ...th a dry duster During the summer months or at other times when the appliance is not in use and is completely cold wipe exterior surfaces with a damp cloth Never allow water or other liquids to drip i...

Страница 15: ...WARRANTY AND CAUSE DAMAGE OR PERSONAL INJURY This Mastercraft product carries a one 1 year LIMITED warranty against defects in workmanship and materials This product is not guaranteed against wear or...

Отзывы: