AUTOMATIC PROCEDURE
Connect and open HP
and LP hoses to the
side of the machine
F1 to continue
F2 to exit
↵
↑
↓
Press F1
▶
to begin hoses flushing, the following screen will be displayed:
Hoses Flushing
Please Wait
ACP>26inHg
■
Hose flushing consists of 4 cleaning rounds, at the end of the 4 phases the following screen will be displayed:
NOTE:
The hose flushing process takes approximately 10 minutes to complete.
DUE TO THE SAFETY ISSUES RELATED TO HYBRID VEHICLES DO
NOT STOP THIS PROCESS.
■
AUTOMATIC PROCEDURE
Disconnect hoses
from machine, then
connect to AC system
Press F4
Charge
↵
Press F4
↵
to continue with the AUTOMATIC PROCEDURE. The following screen will be displayed:
▶
■
RECOVERY/RECYCLING
Open high and low
service port valves
Press F1
Open the high and low pressure taps on the machine and press F1
▶
to begin the RECOVERY/RECYCLING process. During this phase, the graphic
display will show the following:
■
RECOVERY/RECYCLING
Ref recov. 00.00lb
Tp 87 psi T 68.7˚F
Acp 2 psi
Upon completion of recovery, the machine will stop and automatically discharge the used oil from the A/C system if any was present during recovery.
The oil discharge operation lasts 6-14 minutes depending on the ambient temperature and the amount of refrigerant recovered. During the oil
discharge operation, the following screen will be displayed: