28
www.masterproducts.es
3
4
Set the potentiometer value to 100%.
Open the lower hatch of the dispenser (D) to drop the flowers into
the container. With the potentiometer set to 100%, the flowers
will stay on the container walls in a turbulent flow. Lower the
potentiometer level until the movement is uniform and all the
flowers are in continuous contact with the grid. Maintain these
conditions for approximately 1 or 2 minutes to obtain the desired
cut. The cutting time and the value of the potentiometer will be
determined by the humidity and variety of the flowers.
5
7
6
To remove the flowers from the container, increase the value
of the potentiometer to 100% and lift the exit panel to eject the
processed flowers.
Once the work session is finished, turn off the machine by pressing the on/off switch to leave it in the
OFF
state.
The flowers housed in the tube (E) can be extracted by opening
the end cap, or continue to operate and collect them when there
are more.