Master MH-600T-KFA Скачать руководство пользователя страница 15

NEVER LEAVE HEATER UNATTENDED WHILE BURNING 

OR WHILE CONNECTED TO A POWER SOURCE

© 2017, Pinnacle Climate Technologies, Inc. 

Kerosene Forced Air Heater User’s Manual 

15

Limited Warranty

Pinnacle Climate Technologies, Inc.

 warrants this heater 

to the original retail purchaser only, to be free from defects 

in material and workmanship for a period of one (1) year 

from the date of initial purchase. This product must be 

properly installed, maintained and operated in accordance 

with the instructions provided.

Pinnacle Climate Technologies, Inc. 

requires reasonable 

proof of your date of purchase from an authorized retailer 

or distributor.  Therefore, you should keep your sales slip, 

invoice or cancelled check from the original purchase.  

This Limited Warranty shall be limited to the repair or 

replacement of parts, which prove defective under normal 

use and service within the warranty period, and which 

Pinnacle Climate Technologies , Inc.

 shall determine at 

its reasonable discretion. 

This warranty does not apply to products purchased for 

rental use. 

This Limited Warranty does not cover any failures or 

operating difficulties due to normal wear and tear, accident, 

abuse, misuse, alteration, misapplication, improper 

installation or improper maintenance and service by you 

or any third party.  Failure to perform normal and routine 

maintenance on the heater, shipping damage, damage 

related to insects, birds or animals of any kind, and damage 

due to weather conditions are also not covered.   

In addition, the Limited Warranty does not cover damage 

to the finish, such as scratches, dents, discoloration, rust or 

other weather damage, after purchase. 

All transportation costs for the return of damaged product 

or parts will be the responsibility of the purchaser. Upon 

receipt of damaged item, 

Pinnacle Climate Technologies, 

Inc. 

will examine the item and determine if defective. 

Pinnacle Climate Technologies, Inc. 

will repair or replace 

and return the item, freight pre-paid. 

If 

Pinnacle Climate Technologies, Inc. 

finds the item to 

be in normal operating condition, or not defective the item 

will be returned freight collect. This Limited Warranty is 

in lieu of all other express warranties. 

Pinnacle Climate 

Technologies, Inc.

 disclaims all warranties for products 

that are purchased from sellers other than authorized 

dealers or distributors. 

AFTER THE PERIOD OF THE ONE (1) YEAR EXPRESS 

WARRANTY EXPIRES, 

Pinnacle Climate Technologies, 

Inc. 

DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, 

INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES 

OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR 

APPLICATION. FURTHER, 

Pinnacle Climate Technologies, 

Inc. 

SHALL HAVE NO LIABILITY WHATSOEVER TO PURCHASER 

OR ANY THIRD PARTY FOR ANY SPECIAL, INDIRECT, PUNITIVE 

INCIDENTAL, OR CONSEQUENTIAL DAMAGES. 

Pinnacle 

Climate Technologies, Inc. 

assumes no responsibility for 

any defects caused by third parties. This Limited Warranty 

gives the purchaser specific legal rights; a purchaser may 

have other rights depending upon where he or she lives. 

Some states do not allow the exclusion or limitation of 

special, incidental or consequential damages, or limitations 

on how long a warranty lasts, so the above exclusion and 

limitations may not apply to you.  

Pinnacle Climate Technologies, Inc. 

does not authorize 

any person or company to assume for it any other 

obligation or liability in connection with the sale, installation, 

use, removal, return or replacement of its equipment, and 

no such representations are binding on 

Pinnacle Climate 

Technologies, Inc.

Always be sure to specify the model number and serial 

number when making any claim with 

Pinnacle Climate 

Technologies, Inc. 

For your convenience, use the space 

provided below to list this information.

Model #:________________________________

Serial #:________________________________

Date of Purchase: ________________________

Locating Your Serial Number:

Your serial number can be found on a white label on the right side cover of your heater. It will be a 

series of 9 digits. For Example: 131234956. Have your Serial Number ready before calling customer 

service at 800-779-3267.

Содержание MH-600T-KFA

Страница 1: ...56379 USA Toll Free 800 779 3267 Fax 320 251 2922 Web www masterindustrialproducts com Email info pinnacleclimate com 2017 Pinnacle Climate Technologies Inc MAKB 410 User s Manual Operating Instructio...

Страница 2: ...or at high altitudes Risk of burns fire explosion NEVER use fuels such as gasoline benzene paint thinners crankcase drainings or other oil compounds in this heater RISK OF FIRE OR EXPLOSION MASSACHUSE...

Страница 3: ...a minimum of 25 ft from heaters torches portable generators or other sources of ignition All fuel storage should be in accordance with federal state or local authorities having jurisdiction Never use...

Страница 4: ...s for future storage Check the diagram on the following page to be sure that you have all of the parts required to assemble your heater If you find that any parts are missing call 800 779 3267 for ass...

Страница 5: ...xle through wheel support frame Install wheel bushings flat washers S and wheel on axle NOTE When installing wheels tube valve should face out from support frame Figure 2 2 Place flat washers L and co...

Страница 6: ...Here the air is heated and then forced out the front of the heater THE SAFETY SYSTEM Temperature Limit Control This heater is equipped with a Temperature Limit Control designed to turn the heater off...

Страница 7: ...not cooled Do not restart heater until cooling cycle is complete 1 Push OPERATION BUTTON see Figure 5 This will cause heater flame to go out The motor will continue to run during the cooling cycle Thi...

Страница 8: ...ut and drain See Figure 6 2 Using a small amount of kerosene swirl and rinse the inside of the tank NEVER MIX WATER WITH KEROSENE as it will cause rust in side the tank Pour the kerosene out making su...

Страница 9: ...5 5 6 N m Rein stall upper shell NOZZLE Remove dirt in nozzle as needed 1 Remove upper shell 2 Remove fuel line B from burner assembly by using wrench 3 Remove burner head from burner assembly 4 Remov...

Страница 10: ...nscrewing four screws see Figure 10 3 Remove fuel filter from fuel cover 4 Wash fuel filter in clean kerosene 5 Replace fuel filter and fuel cover Fuel filter A on fuel cap 1 Remove fuel cap See Figur...

Страница 11: ...re gauge 10 Replace fuel line and plug in end of filter cover NOTE Use only original equipment replacement parts Use of al ternate or third party components will void any warranty and may cause unsafe...

Страница 12: ...NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE 2017 Pinnacle Climate Technologies Inc Kerosene Forced Air Heater User s Manual 12 Exploded View 1 2 3 4 5 6...

Страница 13: ...17 Pinnacle Climate Technologies Inc Kerosene Forced Air Heater User s Manual 13 Parts List Description MH 400T KFA 1 PCB Assembly 70 027 0800 2 Fuel Cap Assembly 70 006 0200 3 Pneumatic Wheel 70 041...

Страница 14: ...1 Fill tank with fresh kerosene 2 Adjust pump pressure see page 10 3 Clean replace spark plug see page 9 4 Clean replace fuel filter see page 10 5 Clean replace nozzle see page 9 6 Rinse fuel tank wit...

Страница 15: ...em freight pre paid If Pinnacle Climate Technologies Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu...