background image

NEVER LEAVE HEATER UNATTENDED WHILE BURNING, 

CONNECTED TO A POWER SOURCE, OR WHILE 

CONNECTED TO A FUEL SOURCE

© 2014, Pinnacle Products International, Inc. 

Convection Heater User's Manual

Lighting Instructions:

MH-80V-LPC-A

1. 

STOP! Read all of the safety information 

provided with this heater.

2. 

Turn valve on propane cylinder 

COUNTERCLOCKWISE until fully open.

3. 

Press in control knob and turn 

COUNTERCLOCKWISE to 

LOW/IGN 

position.

4. 

If burner does not ignite, turn control knob to 

OFF 

position and repeat the ignition procedure.

5.  Keep control knob pressed in for approximately 

30 seconds before releasing.

6. 

If the flame goes out, wait 5 minuets and 

repeat the ignition and lighting steps.

7. 

After heater ignites, turn the control knob to 

desired heat setting.

Relighting Instructions

1. 

Rotate valve on cylinder 

CLOCKWISE

 to close 

it and wait 5 minuets.

2. 

Relight following the Lighting Instructions, 

steps 1-7.

Shut Down Instructions

1. 

Turn control knob to the 

OFF 

position.

2. 

Rotate valve cylinder 

CLOCKWISE

 to close it.

MH-200V-LPC-A

1. 

STOP! Read all of the safety information 

provided with this heater.

2. 

Turn valve on propane cylinder 

COUNTERCLOCKWISE until fully open.

3. 

Set control valve to 

LIGHT/LOW 

position, 

then wait 15 seconds before step 4.

4. 

Depress the red button on the safety valve, 

admitting gas to the burner. While pressing 

the safety valve, push and release the ignition 

button until the burner lights. 

5.  When the burner lights, continue to keep the 

red safety valve depressed for 30 seconds 

then release. 

6. 

If burner goes out, wait 5 minuets and repeat 

lighting procedure. 

7. 

When burner lights, you can now adjust the 

heat setting to 

HIGH

 

by sliding the control 

valve up to the 

HIGH 

setting. 

NOTE:

 When adjusting heat setting, the control 

valve only needs to slightly slide up to achieve 

HIGH

 setting.

Relighting Instructions

1. 

Rotate valve on cylinder 

CLOCKWISE

 to close 

it and wait 5 minuets.

2. 

Relight following the Lighting Instructions, 

steps 1-7.

Shut Down Instructions

1. 

Rotate valve cylinder 

CLOCKWISE

 to close it.

Operation

EXTREMELY HOT during operation. Do Not touch any metal components while in 

operation. Keep gasoline and any other flammable liquids away from the heater.

WARNING

8

Содержание MH-200V-LPC-A

Страница 1: ...ONING AND OR ELECTRIC SHOCK ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL LA...

Страница 2: ...signed and approved for use as a construction heater in accordance with Standard ANSI Z83 7 2011 CSA 2 14 2011 CHECK WITH YOUR LOCAL FIRE SAFETY AUTHORITY IF YOU HAVE ANY QUESTIONS ABOUT APPLICATIONS...

Страница 3: ...INDOOR USE PERMITTED ONLY FOR The temporary heating of adequately ventilated buildings or structures under construction alteration or repair Provide at least a three square foot 2 800 sq cm opening of...

Страница 4: ...ds the LP cylinder unless it is at least 20 feet from the heater Use only the regulator and hose assembly provided with this heater Inspect the regulator hose assembly prior to each use of the heater...

Страница 5: ...ure 2 Specifications Model MH 80V LPC A MH 200V LPC A BTU 60 000 70 000 80 000 70 000 200 000 Fuel Consumption Lbs hr 2 8 3 2 3 7 3 2 9 3 Heat Settings 3 Variable Maximum Operating Hours 36 31 Require...

Страница 6: ...hipping Retain caps for covering the inlet connector and regulator hose fro storage 3 Inspect heater closely for any damage that may have occurred during shipping If there is any damage return the hea...

Страница 7: ...National Standard for Compressed Gas Cylinder Valve Outlets and Inlets Connections A safety relief valve having direct communications with the vapor space of the LP cylinder The heater must operate o...

Страница 8: ...urn ON the LP cylinder valve and check for leaks with soap solution Checking For Leaks To check for leaks make up a 50 50 solution of dish soap and water Apply this solution to all gas connections If...

Страница 9: ...ise to close it MH 200V LPC A 1 STOP Read all of the safety information provided with this heater 2 Turn valve on propane cylinder COUNTERCLOCKWISE until fully open 3 Set control valve to LIGHT LOW po...

Страница 10: ...R Storage Maintenance Always disconnect the heater from the LP cylinder before putting the heater into storage If for any reason the heater is to be stored indoors the tank MUST be disconnected from t...

Страница 11: ...h time for thermocouple to warm up 2 Gas pressure too low 3 Thermocouple needs replacing or loose 4 Control valve damaged 1 Keep Control Valve depressed for at least 30 seconds 2 Check cylinders for a...

Страница 12: ...SOURCE OR WHILE CONNECTED TO A FUEL SOURCE 2014 Pinnacle Products International Inc Convection Heater User s Manual 1 1 2 2 3 3 4 4 5 6 7 8 9 9 10 10 11 11 12 12 13 14 13 14 15 16 17 17 18 19 20 18 1...

Страница 13: ...rol Valve Ball Valve 24 015 0003 7 Piezo Lighter 24 122 0003 8 Valve Assembly 24 011 0020 9 Wind Screen 24 526 0001 24 526 0001 10 Base 24 501 0010 24 501 0011 11 Thermocouple 24 091 0002 24 091 0003...

Страница 14: ...turned freight collect This Limited Warranty is in lieu of all other express warranties Pinnacle Products International Inc disclaims al warranties for products that are purchased from sellers other t...

Страница 15: ..._____ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ___________...

Страница 16: ...2014 Pinnacle Products International Inc 668 Stony Hill Road 302 Yardley PA 19067 USA Toll Free 800 641 6996 Fax 215 891 8461 Web www pinnacleint com Email info pinnacleint com...

Отзывы: