9
102422
TROUBLE-
SHOOTING
Wrong pump pressure
Dirty air output, air intake,
and lint filters
Dirty fuel filter
Dirt in nozzle
Dirty photocell lens
Bad flame-out control
See Pump Pressure
Adjustment, page 14.
See Air Output, Air Intake
and Lint Filters, page 14.
See Fuel Filter, page 11.
See Nozzle, pages 15 and
16.
Clean photocell lens.
Replace flame-out control.
WARNING
Never service heater while it is plugged in, operating, or hot.
Severe burns and electrical shock can occur.
OBSERVED FAULT
POSSIBLE CAUSE
REMEDY
Heater ignites, but
flame-out control
shuts off heater after
a short period of
time.
Heater will not
ignite, but motor runs
for a short period of
time.
Wrong pump pressure
Carbon deposits on spark
plug and/or improper gap
Dirty fuel filter
Dirt in nozzle
Water in fuel tank
Electronic ignitor not
grounded (earthed)
Bad electronic ignitor
See Pump Pressure
Adjustment, page 14.
See Spark Plug, pages 12
and 13.
See Fuel Filter, page 11.
See Nozzle, pages 15 and
16.
Drain and flush fuel tank
with clean kerosene.
See Storing, Transport-
ing, or Shipping, page 8.
Make sure electronic
ignitor mounting is tight.
Replace electronic
ignitor.
WARNING: High voltage!
Flame-out control not reset
Binding pump rotor
Motor does not start
when heater is
plugged in, fan
rotates slowly or
does not turn.
Reset flame-out control
button, see Figures 5 and
6, page 7.
If fan is hard to turn, see
Pump Rotor, page 17.