9
099605
Continued
Item
How Often
How To
Spark plug
Clean and regap every 600
See Spark Plug, pages 12 and 13.
hours operation or replace
as needed.
Fan blades
Clean every season or as needed. See Fan, page 19.
Motor
Not required/permanently lubricated
TROUBLE-
SHOOTING
OBSERVED FAULT
POSSIBLE CAUSE
REMEDY
Wrong pump pressure
Dirty air output, air intake,
and lint filters
Dirty fuel filter
Dirt in nozzle
Dirty photocell lens
Bad flame-out control
Heater ignites, but
flame-out control
shuts off heater after
a short period of time
(EDI models only).
See Pump Pressure
Adjustment, page 14.
See Air Output, Air Intake
and Lint Filters, page 14.
See Fuel Filter, pages 10
and 11.
See Nozzle, pages 15 thru
17.
Clean photocell lens.
Replace flame-out control.
Heater will not
ignite, but motor runs
for a short period of
time.
Wrong pump pressure
Carbon deposits on spark
plug and/or improper gap
Dirty fuel filter
Dirt in nozzle
Water in fuel tank
Electronic ignitor not
grounded (earthed)
Bad electronic ignitor
See Pump Pressure
Adjustment, page 14.
See Spark Plug, pages 12
and 13.
See Fuel Filter, pages 10
and 11.
See Nozzle, pages 15 thru
17.
Drain and flush fuel tank
with clean kerosene. See
Storage, page 8.
Make sure electronic
ignitor mounting is tight.
Replace electronic
ignitor.
Motor does not start
when heater is
plugged in, fan
rotates slowly or
does not turn.
Flame-out control not reset
(EDI models only)
Binding pump rotor
Reset flame-out control
button, see Figures 6 thru
8, pages 7 and 8.
If fan is hard to turn, see
Pump Rotor, page 18.
WARNING
Never service heater while it is plugged in, operating, or hot.
Severe burns and electrical shock can occur.
WARNING: High voltage!