8
Warning: IF WATER ENTERS THE TANK TOO FAST, ALL THE
RESIN WILL BE FLUSHED TO DRAIN DURING START UP.
2. When water is running steadily at the drain, open the bypass
valve’s inlet and outlet to their maximum position.
3. Simultaneously press the SET and UP buttons on the controller
for 1 second then release, the motor will advance the cam to C2.
Once C2 is displayed simultaneously press the SET and UP
buttons on the controller for 1 second then release, the motor will
advance the cam to C3. Repeat this procedure until the timer
enters the C7 (FAST RINSE) position. The softener will go
through the rinsing cycle and then automatically advance to
(BRINE REFILL) C8 and fill the brine tank with the proper amount
of water.
4. The control valve will advance to C0 (REGENERATION
COMPLETE) and Time of Day will be displayed. This is
treated water.
Logix Control Valve Timer Settings:
Note:
The control valve is set at the factory. You only need to set
the time of day and regeneration time if required, which is preset
at 2 am.
Figure 5