Electrical Requirements
 

Always follow all local electrical codes when installing our water 
treatment equipment. 

1.  Provide an 115v/60Hz properly grounded dedicated electrical    
     Outlet. (I

t’s very important that the polarity be correct) 

      

Avoid using outlets that are switch controlled.

  

2.  Maximum amperage required is 5 amps. 
3.  Make sure the electrical service provides power 24 hours per day.  
     We recommend installing a

 surge protector 

to protect unit from   

     power surges, which are not covered by warranty.  
                                                          

 

                                                                                                          

 

 
Filling Filter with Water: 
 

1.  Connect the MCA control valve transformer into the electrical outlet 

provided. 

2.  Press and hold the Up and Down arrows simultaneously for three 

seconds until the drive motor starts.  When the drive motor stops, the 
display will read 

“C1” backwash position. 

3.  Open the inlet ball valve a ¼ turn of its full open position to allow 

water to enter the water filter mineral tank slowly.  The water is going 
to enter the tank from the bottom of the distributor pipe and leave the 
tank from the top.  This will slowly purge all the air from the tank.    

IF WATER ENTERS THE TANK TOO FAST, ALL THE RESIN WILL 
BE FLUSHED TO DRAIN DURING START UP. 

4.  When only water is running to the drain, open the inlet and outlet ball 

valves fully.    

5.  Once the drive motor stops, press the Up button to advance the 

control valve to the fa

st rinse position.  The display will read “C4”.   

The fast rinse position will rinse the filter tank.   

 
NOTE:  THE TIMER WILL AUTOMATICALLY ADVANCE TO THE 
SERVICE POSITION AND THE DISPLAY WILL READ TIME OF DAY. 
 
 

Содержание Clarifier MCA Series

Страница 1: ...MCA Clarifier Series Residential Filters 2022 MASTER Water Conditioning Corp Installation and Operation Manual...

Страница 2: ...Loading 2 Clarifier Control Valve 2 4 Service and Drain Piping 4 5 Electrical Supply 6 Filling Filter with Water 6 Control Valve Timer Settings 7 Final Check 7 Default Timer Display and Manual Regene...

Страница 3: ...CC 10 N A 1 5 CF Carbon Centaur MCA AC ACC 13 N A 2 0 CF Carbon Centaur MCA AN 10 N A 1 0 CF Calcite 0 5 CF NS Mix MCA AN 13 N A 2 0 CF Calcite MCA FE 10B N A 1 5 CF Birm MCA FE 13B N A 2 0 CF Birm MC...

Страница 4: ...media provided with the unit into the top of the tank Model Gravel 1 Sand 0 Sand 45 Sand 0 Sand Philterkol MCA MM 10 N A 20 lbs 12 lbs 37 lbs 25 lbs 19 lbs MCA MM 13 N A 25 lbs 16 lbs 50 lbs 35 lbs 2...

Страница 5: ...rection two threaded connections for the tail piece kit and two o ring seal connections with nuts for the control valve Align the insert connection ends with o ring seals and nuts to the inlet and out...

Страница 6: ...alve or bypass If Schedule 80 PVC is used make sure to follow the proper primer and solvent instructions 3 The drain line connection is npt or optional 5 8 OD and is located on the top left of the val...

Страница 7: ...orp Well Tank NOTE All Master Water Conditioners must be installed after the well tank or water meter if its public water supply Master Water Conditioner Air Gap Drain Untreated TYPICAL PIPING LAYOUT...

Страница 8: ...or three seconds until the drive motor starts When the drive motor stops the display will read C1 backwash position 3 Open the inlet ball valve a turn of its full open position to allow water to enter...

Страница 9: ...egen and the hour will be blinking 1 Use the UP or DOWN arrows to adjust hour 2 Press the CLOCK button 3 Press the UP or DOWN arrows to adjust the minutes 4 Press the CLOCK button Regeneration Frequen...

Страница 10: ...8...

Страница 11: ...9...

Страница 12: ...Water Quality When Unit is in Service Position Cause Solution The bypass valve is open or defective Insure that the bypass valve is in the service position Excessive water usage Set the timer to rege...

Страница 13: ...nlet piping Distributor pipe is plugged Clean or replace the distributor pipe Problem Control Valve Cycles Continuously Cause Solution Defective timer circuit board Replace the circuit board Problem T...

Страница 14: ...ap assembly Replace drive gear or drive cap assembly Broken piston retainer Replace piston retainer Broken main or regenerate piston Replace main or regenerate piston Problem Control valve does not re...

Страница 15: ...or mechanical stall Defective motor damaged wiring poor wire connection or mechanical component failure E3 Motor running too long or timeout during piston relocating Damaged wiring poor wire connecti...

Страница 16: ...14...

Страница 17: ...15...

Страница 18: ...16...

Страница 19: ...l be void in the event of damages from external sources or where the conditioner has been operated at pressure in excess of 100 pounds per square inch or at a temperature greater than 100 degrees F or...

Страница 20: ...P1 8 50 8 4 1 99 P2 8 70 10 6 1 99 P3 12 70 12 8 1 99 P4 10 50 Skipped 8 1 99 P5 4 50 Skipped 4 1 99 P6 12 6 Skipped 12 1 99 P7 6 Skipped Skipped 4 Skipped P8 10 Skipped Skipped 6 Skipped P9 14 Skippe...

Страница 21: ...LOCK CLOCK CLOCK REGENERATE NOW PRESS BOTH ARROWS FOR 4 SECONDS MOTOR WILL START REGENERATE TONIGHT PRESS BOTH ARROWS FOR 1 SECOND MANUAL REGENERATION AND SIMULTANEOUSLY ADVANCE THROUGH EACH REGENERAT...

Страница 22: ...Regen d1 Do not Regen OR d2 Regen Regen d2 Do not Regen CHOOSE REGEN DAY OF WEEK MONDAY CONTINUE THROUGH d7 OR Display Day of Week D1 Sunday D2 Monday D3 Tuesday D4 Wednesday D5 Thursday D6 Friday D7...

Страница 23: ...SECONDS 1 Regen Hour SET HOUR OF DAY FOR REGENERATION 4 Days to Regen SET DAYS BETWEEN REGENERATIONS 1 99 DAY OPTION CLOCK AND OR OR CLOCK 00 Regen Minutes SET MINUTES OF DAY FOR REGENERATION OR CLOC...

Страница 24: ...Error Codes...