background image

5

TEM/TEL SERIES

ENDLESS REMOTE GLASS DOOR MERCHANDISERS 

WITH TOP MOUNTED COIL

REQUIRED CONDENSING UNITS

Use this chart to determine the correct condensing unit for your endless lineup. 
Unless already indicated, add suffix "B" for one phase or "C" for three phase model.

NO. OF 

DOORS

+35°F AVERAGE PRODUCT TEMP. 

+20°F SUCTION

75°F AIR CONDITIONED STORE

55% RELATIVE HUMIDITY

-3°F AVERAGE PRODUCT TEMP. 

-11°F SUCTION

75°F AIR CONDITIONED STORE

55% RELATIVE HUMIDITY

-12°F AVERAGE PRODUCT TEMP. 

-18°F SUCTION

75°F AIR CONDITIONED STORE

55% RELATIVE HUMIDITY

COND. UNIT REQUIRED FOR AIR TEMP. 

ENTERING CONDENSER*

COND. UNIT REQUIRED FOR AIR TEMP. 

ENTERING CONDENSER*

COND. UNIT REQUIRED FOR AIR TEMP. 

ENTERING CONDENSER*

90°F

100°F

110°F

90°F

100°F

110°F

90°F

100°F

110°F

2

MHHZ0071B MHHZ0071B MHHZ0071B MHLZ0071 MHLZ0071 MHLZ0071 MHLZ0091 MHLZ0091 MHLZ0091

3

MHHZ0071B MHHZ0071B MHHZ0071B MHLZ0071 MHLZ0091 MHLZ0091 MHLZ0091 MHLZ0121 MHLZ0121

4

MHHZ0071B MHHX0081B MHHX0081B MHLZ0091 MHLZ0091 MHLZ0121 MHLZ0121 MHLZ0121 MHLZ0121

5

MHHZ0081B MHHZ0081B MHHZ0111 MHLZ0091 MHLZ0121 MHLZ0121 MHLZ0121 MSLZ0151

MSLZ0181

6

MHHZ0111 MHHZ0111 MHHZ0111 MHLZ0121 MHLZ0121 MSLZ0151

MSLZ0151

MSLZ0181

MSLZ0221

7

MHHZ0111 MHHZ0111 MHHZ0171 MHLZ0121 MSLZ0151

MSLZ0181

MSLZ0181

MSLZ0221

MSLZ0221

8

MHHZ0171 MHHZ0171 MHHZ0171 MSLZ0151

MSLZ0181

MSLZ0181

MSLZ0221

MSLZ0221

MSLZ0221

9

MHHZ0171 MHHZ0171 MHHZ0191 MSLZ0181

MSLZ0181

MSLZ0221

MSLZ0221

MSLZ0221

BSLZ0750

10

MHHZ0171 MHHZ0191 MHHZ0191 MSLZ0181

MSLZ0221

MSLZ0221

MSLZ0221

BSLZ0750

BSLZ0750

11

MHHZ0191 MHHZ0191 MHHZ0221 MSLZ0221

MSLZ0221

MSLZ0221

BSLZ0750

BSLZ0750

BSLZ0750

12

MHHZ0191 MHHZ0221 MHHZ0221 MSLZ0221

MSLZ0221

BSLZ0750

BSLZ0750

BSLZ0750

BSLZ1000

13

MHHZ0191 MHHZ0221 MHHZ0251 MSLZ0221

BSLZ0750

BSLZ0750

BSLZ0750

BSLZ1000

BCLZ0750

14

MHHZ0221 MHHZ0251 MHHZ0251 BSLZ0750

BSLZ0750

BSLZ0750

BSLZ1000

BSLZ1000

BSLZ1500

15

MHHZ0251 MHHZ0251 MHHZ0301 BSLZ0750

BSLZ0750

BSLZ1000

BSLZ1000

BSLZ1000

BSLZ1500

16

MHHZ0251 MHHZ0251 MHHZ0301 BSLZ0750

BSLZ1000

BSLZ1000

BSLZ1000

BSLZ1500

BSLZ1500

17

MHHZ0251 MHHZ0301 MHHZ0331 BSLZ0750

BSLZ1000

BSLZ1000

BSLZ1500

BSLZ1500

BSLZ1500

18

MHHZ0301 MHHZ0301 MHHZ0331 BSLZ1000

BSLZ1000

BSLZ1500

BSLZ1500

BSLZ1500

BSLZ1500

19

MHHZ0301 MHHZ0331 MHHZ0331 BSLZ1000

BSLZ1000

BSLZ1500

BSLZ1500

BSLZ1500

BSLZ1500

20

MHHZ0301 MHHZ0331 MHHZ0431 BSLZ1000

BSLZ1500

BSLZ1500

BSLZ1500

BSLZ1500

BCLZ1500

21

MHHZ0331 MHHZ0331 MHHZ0431 BSLZ1000

BSLZ1500

BSLZ1500

BSLZ1500

BSLZ1500

BCLZ1500

22

MHHZ0331 MHHZ0431 MHHZ0431 BSLZ1500

BSLZ1500

BSLZ1500

BSLZ1500

BCLZ1500

BCLZ1500

23

MHHZ0331 MHHZ0431 MHHZ0431 BSLZ1500

BSLZ1500

BSLZ1500

BSLZ1500

BCLZ1500

BCLZ1500

24

MHHZ0431 MHHZ0431 MHHZ0431 BSLZ1500

BSLZ1500

BSLZ1500

BCLZ1500

BCLZ1500

BCLZ1500

25

MHHZ0431 MHHX0441 MHHZ0501 BSLZ1500

BSLZ1500

BSLZ1500

BCLZ1500

BCLZ1500

BCLZ1500

*Condensing unit and line size based on 100' line run.

See the Master-Bilt 

Condensing Unit & Refrigeration Systems I/O Manual

 for other conditions.

For other than high capacity condensing units, consult factory. 