12

EVAP.

FANS

W

BK

TEMP.

CONT.

J BOX

CONDENSATE
PAN HEATER

115/60/1

W

BK

COMPRESSOR

COND

FAN

 THERM.

DIGITAL

WIRING DIAGRAM

07/19/95

TAC-27,-27HD

TC27

B

W/BL

W

R

R

R

SWITCH

FRAME

DOOR

HEATER

LIGHT

LIGHT

INCANDESCENT

NEMA #5-15P

TRANSFORMER

 

 
 

Содержание TAF-27

Страница 1: ...Installation Operations Manual Master Bilt Products 908 Highway 15 North New Albany MS 38652 Phone 800 684 8988 PN 217 90000 10 16 03 ...

Страница 2: ...2 ...

Страница 3: ...ns 7 Location 7 Dimensional Data 7 STARTING PROCEDURE 8 FINAL CHECK LIST 8 SERVICE INSTRUCTIONS 9 MASTER BILT PART NUMBERS 10 SALE AND DISPOSAL 11 WIRING DIAGRAMS TAC27 12 WIRING DIAGRAMS TAC27R 13 WIRING DIAGRAMS TAC48 14 WIRING DIAGRAMS TAC48R 15 WIRING DIAGRAMS TAC74 16 WIRING DIAGRAMS TAC74R 17 WIRING DIAGRAMS TAF27 18 WIRING DIAGRAMS TAF48 TAF74 19 WIRING DIAGRAMS TAF ALL REMOTE AND QUICK CON...

Страница 4: ...able The Master Bilt TAF TAC should not be positioned where it is directly exposed to rays of sun or near a direct source of radiant heat or air flow This will adversely affect the case and will result in poor performance If this case is to be located against a wall there should be at least 4 space between the wall and the back of the case This space will allow for the circulation of air behind th...

Страница 5: ...ses or services your cabinet is thoroughly familiar with all safety information and procedures Important safety information is presented in this section and throughout this section and throughout the manual The following signal words are used in the warnings and safety messages DANGER Severe injury or death will occur if you ignore the message WARNING Severe injury or death can occur if you ignore...

Страница 6: ... Stock cases as quickly as possible exposing only small quantities to store temperatures for short periods of time 6 When replacing burned out fluorescent tubes be sure that the electrical power to the lighting circuit is turned off MECHANICAL Remove front grille and check refrigeration lines to see that they are free not touching each other or compressor Spin condenser fan blade to see that it is...

Страница 7: ...ion should be made by qualified personnel to determine the source of the moisture or liquid The investigation should determine if the cabinet is malfunctioning or if there is a drain pipe leaking ELECTRICAL WARNING Before servicing electrical components in the case or the doors or door frames make sure all power to case is off Always use a qualified technician INSTALLATION INSTRUCTIONS To comply w...

Страница 8: ...115 60 1 circuit The TAF 74 models have two junction boxes mounted on top of the cabinet at the right rear for permanent connection to power One junction box is labeled 115v black white and green lead the other is labeled 230v black red and green lead These boxes should be connected to their respective power source Check inside the cabinet for the power requirement for each cabinet The label is lo...

Страница 9: ...S Trouble Shooting Guide 1 High head pressure and high back pressure A Condenser coil clogged or restricted B Condenser fan motor defective 2 Low back pressure and low head pressure A Restriction in system B Refrigerant undercharged C Leak in system 3 Pressures normal cabinet warm A Coil blocked with frost or ice see 4 B Refrigerant undercharged C Control set too warm D Air screen disturbance 4 Co...

Страница 10: ... 01450 11 01450 11 01451 Coil Defrost Heater 17 00443 17 09113 17 09076 Condensate Heater 17 00421 17 00421 17 00421 17 00421 17 00421 17 00421 Condensing Unit 01 01471 01 01471 01 01472 01 01488 01 01510 01 01487 Def Term Fan Delay 19 13195 19 13195 19 13195 Digital Thermometer 19 13271 19 13271 19 13271 19 13271 19 13271 19 13271 Door Frame Heater 17 09148 17 09144 17 09144 17 09449 17 09142 17 ...

Страница 11: ...t If you need replacement labels or manuals Master Bilt will provide them free Contact the customer service department at Master Bilt at 800 684 8988 The customer service department at Master Bilt should be contacted at the time of sale or disposal of your cabinet so records may be kept of its new location If you sell or give away your Master Bilt cabinet and you evacuate the refrigerant charge be...

Страница 12: ...BK TEMP CONT J BOX CONDENSATE PAN HEATER 115 60 1 W BK COMPRESSOR COND FAN THERM DIGITAL WIRING DIAGRAM 07 19 95 TAC 27 27HD TC27 B W BL W R R R SWITCH FRAME DOOR HEATER LIGHT LIGHT INCANDESCENT NEMA 5 15P TRANSFORMER ...

Страница 13: ...NSING UNIT POWER TERMINALS OR TO LIQUID LINE SOLENOID VALVE COIL TERMINALS CONDENSING UNIT ON SEPERATE POWER SUPPLY J BOX W BR 115 60 1 CONTROL CIRCUIT 07 19 95 WIRING DIAGRAM TAC 27 R TC27R INCANDESCENT LIGHT LIGHT HEATER DOOR FRAME SWITCH R R R W W B B TRANSFORMER DIGITAL THERM ...

Страница 14: ...ONDENSATE PAN HEATER 115 60 1 W BK COMPRESSOR COND FAN THERM DIGITAL WIRING DIAGRAM 07 19 95 TAC 48 48HD TC48 INCANDESCENT LIGHT FRAME DOOR HEATER LIGHT SWITCH LIGHT HEATER DOOR FRAME SWITCH NEMA 5 15P TRANSFORMER R R R R B W R W W W B B ...

Страница 15: ...NDENSING UNIT POWER TERMINALS OR TO LIQUID LINE SOLENOID VALVE COIL TERMINALS CONDENSING UNIT ON SEPERATE POWER SUPPLY J BOX W BR 07 19 95 115 60 1 CONTROL CIRCUIT THERM DIGITAL INCANDESCENT LIGHT FRAME DOOR HEATER LIGHT SWITCH LIGHT HEATER DOOR FRAME SWITCH TRANSFORMER R R R R B W R W W W B B TC48R ...

Страница 16: ...AN HEATER 115 60 1 BK W THERM DIGITAL WIRING DIAGRAM 07 19 95 TC74 B B W W W R R R R R SWITCH FRAME DOOR HEATER LIGHT SWITCH LIGHT HEATER DOOR FRAME LIGHT INCANDESCENT FRAME DOOR HEATER LIGHT SWITCH R R W B NEMA 5 15P TRANSFORMER INCANDESCENT LIGHT W R TAC 74 74HD W B ...

Страница 17: ...NDENSING UNIT POWER TERMINALS OR TO LIQUID LINE SOLENOID VALVE COIL TERMINALS CONDENSING UNIT ON SEPERATE POWER SUPPLY 07 19 95 R B W R R SWITCH LIGHT HEATER DOOR FRAME INCANDESCENT LIGHT FRAME DOOR HEATER LIGHT SWITCH LIGHT HEATER DOOR FRAME SWITCH R R R R R W W W B B TRANSFORMER DIGITAL THERM TC74R W R INCANDESCENT LIGHT ...

Страница 18: ... EVAP POWER SUPPLY 115 60 1 NEMA 5 20P LIMIT SW HEATER FAN DELAY THERMOSTAT DEFROST TERMINATION COMPRESSOR COND FAN DIGITAL THERM TM TM SWITCH 1 1 2 2 3 3 3 3 N N 4 4 X X TIMER W BK W Y OR BR BL BK R CONT PRES OPTIONAL W Y TEMP CONT OR BR BK R G 3 2 1 R W DRAIN LINE HEATER BL BK BK BK W W ELECTRICAL TRAY EVAPORATOR HOUSING DIGT THER TRANSFORMER EVAP FAN W W W W W W W W BK BK BK BK BK BK Y OR BL W ...

Страница 19: ...EATER FRAME DOOR LIGHT SWITCH LIGHT INCANDESCENT LIGHT SWITCH LIGHT SWITCH SWITCH LIGHT LIGHT SWITCH SWITCH LIGHT BK W R W WHEN PROVIDED R R R W R R R R CONDENSATE EVAPORATOR DEFROST HEATER SAFETY HEATER FAN DELAY DEFROST TERM 2 1 3 DRAIN LINE HTR TEMP CONT R W R W R W R W R W INCANDESCENT LIGHT WHEN PROVIDED DIGITAL THERMOMETER COMPRESSOR COND FAN BR BK OR YEL EVAP FAN EVAP FAN WHEN PROVIDED TAF ...

Страница 20: ...CT 208 230 60 1 TO CONDENSING UNIT 208 230 60 1 OR BL W Y W OR BK R G BR R R IF PROVIDED OR THERM DIGITAL DRAIN LINE HEATER TSFR J BOX 115 60 1 COND PAN HTR W BK SWITCH LIGHT R HEATER DOOR FRAME INCANDESCENT W R W R LIGHT R HEATER HEATER DOOR FRAME FRAME DOOR SWITCH LIGHT INCANDESCENT LIGHT BK W R FIELD MOUNTED SOLENOID BK W G SWITCH LIGHT DOOR 3 IF PROVIDED R R BK W W R BK W W W W BK BK W BK BR B...

Отзывы: