PLAN VIEW

SIDE VIEW

ELEVATION VIEW

��������������������

��������������������

��������������������

TAC/TAF SERIES

FOODSERVICE SOLID DOOR REACH-INS

TECHNICAL SPECIFICATIONS

LISTINGS

HOOKUP

BID SPECIFICATIONS

Item no. TAC-_____HDSA and/or Item no. 
TAF-_____HDSA.

Provide_______(         ) Medium Temp 

Foodservice Solid Door Reach-in(s), and/or 
_______(         ) Low Temp Foodservice Solid 
Door Reach-In(s). Master-Bilt model no(s). 
TAC-_____HDSA and/or TAF_____HDSA.

Cabinet to be constructed of stainless steel 

interior and exterior. TAF models will be 
equipped with an electronically controlled 

1197-7/09-web

©Master-Bilt Products division of Standex International, Inc. All rights reserved. Printed in U.S.A.

TAC MODELS: Via plug in, 8 foot long, flexible 3 wire 14/3 cord    
 

with molded plug. 20 amp service is required for all models.

TAF-27HDSA: Via plug in, 8 foot long, flexible 3 wire 14/3 cord with  
 

molded plug. 15 amp service is recommended.

TAF-48HDSA: Hardwired
TAF-74HDSA: Hardwired with separate junction boxes for 115V and 
 

208- 230V and with a maximum 20 amp fuse. 

monitoring system as well as an automatic 
defrost with double failsafe override.

All models to have digital thermometer 

(built into electronic controller interface on 
TAF models), electric condensate evaporator, 
heavy-duty casters, three welded wire, gray 
epoxy-coated shelves per section. Doors will 
be self-closing with 90° hold-open feature, 
locking horizontal handles and door frame 
heater. 

The refrigeration system will be top 

mounted and self-contained using R-134a 
refrigerant in TAC models and R-404A in TAF 
models. The temperature range will be 34° 
to 41°F (1° to 5°C) for TAC models and 0° to 
-20°F (-18° to -29°C) for TAF models. 

Cabinet to have standard limited 4 year 

extended compressor warranty and 1 year 
limited parts and labor warranty. Cabinet to 
be UL, C-UL and NSF listed.

NEMA 5-20P
(TAC MODELS 
& TAF-27HDSA)

MODEL

DIMENSIONS

(in.)

DIMENSIONS

(mm)

VOLTS**

AMPS

UNIT

H.P.

NO. OF

DOORS

NO. OF 

SHELVES

STANDARD
SHELF SIZE

(in inches)

CAP.

CU. 

FT.

SHIP

CU. 

FT.

SHIP

WT.

LB/KG

L

D

H*

L

D

H*

MEDIUM TEMP

TAC-27HDSA

31

35

3

/

4

80

1

/

2

787

908 2045

115

12.1

1/2

1

3

25

1

/

4

 x 26

25.4

76.0 355/161

TAC-48HDSA

52

35

3

/

4

80

1

/

2

1321 908 2045

115

13.1

1/2

2

6

22

1

/

2

 x 26

45.9 119.0 465/211

TAC-74HDSA

78

35

3

/

4

80

1

/

2

1981 908 2045

115

15.0

3/4

3

9

22

1

/

2

 x 26

71.4 174.0 650/295

LOW TEMP

TAF-27HDSA

31

35

3

/

4

80

1

/

2

787

908 2045

115

10.5

3/4

1

3

25

1

/

4

 x 26

25.4

76.0 385/175

TAF-48HDSA

52

35

3

/

4

80

1

/

2

1321 908 2045 115/208-230

5.0/7.5

1

2

6

22

1

/

2

 x 26

45.9 119.0 540/245

TAF-74HDSA

78

35

3

/

4

80

1

/

2

1981 908 2045 115/208-230 6.2/11.2 1

1

/

2

3

9

22

1

/

2

 x 26

71.4 174.0 670/305

*Height includes casters. **TAF-48HDSA and TAF-74HDSA operate on a minimum of 208 volts. A voltage boosting transformer (part no. 39-01087) 
must be used when the supply voltage is less than 208 volts. 