Warranty Claims

All claims for labor or parts must be made directly through Turbo Air. If unit was manufactured more than one year,
proof of purchase must be faxed in or sent with claim. All claims should include: model number of the unit, the serial
number of the cabinet, and all pertinent information supporting the existence of the alleged defect.
If compressor is replaced under warranty, Turbo Air will either request the compressor or compressor tag be returned.
Compressor or tag must be returned with all information related to the unit.  Any action or breach of these warranty
provisions must be commenced within one year after said cause of action has occurred.

One Year Parts & Labor Warranty

Turbo Air warrants to the original purchaser of every new Turbo Air refrigerated unit, the cabinet and all parts thereof,
to be free from defects in material or workmanship, under normal and proper use and maintenance service as
specified by Turbo Air and upon proper installation and start-up in accordance with the instruction packet supplied
with each Turbo Air unit. Turbo Air’s obligation under this warranty is limited to a period of one (1) year from the date
of original installation or 15 months after shipment date from Turbo Air, whichever occurs first.
Any parts, covered under this warranty, that are determined by Turbo Air  to have been defective within one (1) year
of original installation or fifteen (15) months after shipment date from manufacturer, whichever occurs first, is limited to
the repair or replacement, including labor charges, of defective parts or assemblies. The labor warranty shall include
standard straight time labor charges only and reasonable travel time, as determined by Turbo Air.

Additional Four Year Compressor Warranty

In addition to the one (1) year warranty stated above, Turbo Air warrants its hermetically sealed compressor to be free
from defects in both material and workmanship under normal and proper use and maintenance service for a period of
four (4) additional years from the date of original installation, but not to exceed five (5) years and three (3) months
after shipment from the manufacturer.
Compressor determined by Turbo Air to have been defective within this extended period will, at Turbo Air’s option, be
either repaired or replaced with a compressor or compressor parts of similar design and capacity.
The four (4) year extended compressor warranty applies only to hermetically sealed parts of the compressor and
does not apply to any other parts or components, including, but not limited to, cabinet, paint finish, temperature
control, refrigerant, metering device, driers, motor starting equipment, fan assembly or and other electrical
component, etcetera.

404A / 134A Compressor Warranty

The four-year compressor warranty detailed above will be voided if the following procedure is not carefully adhered to:
1.

This system contains R404A or R134A refrigerant and polyolester lubricant. The polyol ester lubricant has
rapid moisture absorbing qualities. 

2. 

Drier replacement is very important and must be changed when a system is opened for servicing.  A 620
copper drier or better is highly recommended.

3. 

Micron level vacuums must be achieved to insure low moisture levels in the system. 500 microns or lower
must be obtained.

4. 

When compressor is grounded, suction filter drier and 620 drier or better must be replaced.

5. 

Compressor must be obtained through Turbo Air Inc., unless otherwise specified in writing, through Turbo
Air’s warranty department.

Warranty

SPT-24,48,72/UC-28SR,48DR,(영)  2003.1.13 9:58 AM  페이지9

Содержание SPT-28

Страница 1: ...ter Refrigerator Freezer Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment Full Stainless Steel Visible Exterior SPT 28 SPT 48 SPT 72 UC 28SR UC 48DR UC 72TR ...

Страница 2: ... H P V Hz REFRIGERANT AMPS WEIGHT SPT 48 1 3 115V 60Hz R 134a 5 0A 180lbs SPT 28 1 4 115V 60Hz R 134a 5 5A 128lbs SPT 72 5 8 115V 60Hz R 134a 10 8A 385lbs The serial number is located on the rating label which is on the left interior wall Please retain the unit s serial number for service purpose SERIAL NUMBER Undercounter Refrigerator MODEL COMP H P V Hz REFRIGERANT AMPS WEIGHT UC 48DR 1 5 115V 6...

Страница 3: ... Box 3 INSTALLATION OF HANDLE 1 Screw the castor in rear side and the castor brakes in front side by using castor wrench 2 Use the castor shims to level the cabinet if necessary by inserting them to stems of the castors COVER CABINET TOP DOOR ROTATION CASTOR WITH BRAKE 2EA CASTOR 2EA C A B I N E T WASHER BOLT HANDLE LID 4 INSTALLATION OF CASTOR AND CASTOR BRAKE ...

Страница 4: ...lt 5 HOW TO CLEAN THE PAN SUPPORTER Drain Pan Pan Guide Pan Pan Supporter 1 Remove the Guide Pans and Pans Then pull out the Pan Supporter Clean the pan supporter and reinstall in place MODEL SPT 28 SPT 48 SPT 72 ...

Страница 5: ...ng enough floor to support the total weight of the cabinet and any other contents 3 DO NOT PLACE NEAR HEAT Be sure to avoid hot corners and locations near stoves High ambient temperature will make much lower cooling efficiency 4 INDOOR USAGE ONLY Be sure to install this unit indoor So it should prohibit getting wet from the rain 5 STABILIZING Make sure the unit is installed in a stable condition w...

Страница 6: ...eeded 3 CLEAN THE GASKET The door gasket should be cleaned frequently to maintain proper sealing 4 CHECK AFTER CLEANING Check the unit again for safety Check that the unit is operating properly 1 POWER CORD Be sure the power cord is connected to the proper voltage A protected circuit of the correct voltage and amperage must be run for connection of the line cord Turn off the power switch before di...

Страница 7: ...ntrol is Normal 3 Setting toward Cool for higher temperature and Cold for lower temperature 4 The thermostat controls compressor s on off by sensing inside temperature 7 Master bilt BASIC OPERATION COLD OFF NORMAL COOL UC 28SR COLD OFF NORMAL COOL UC 48DR COLD OFF NORMAL COOL SPT 28 COLD OFF NORMAL COOL SPT 48 COLD OFF NORMAL COOL UC 72TR SPT 72 ...

Страница 8: ...rrectly The backside of the unit is too close to the wall The tray is not in the correct position High moisture air can produce dewdrops during rainy seasons The door is opened too frequently or left open too long Damp food is stored The door is bent The unit is not level The door gasket has come out Turn the temperature dial to a warmer colder setting Check the power cord to make sure the unit is...

Страница 9: ...or charges only and reasonable travel time as determined by Turbo Air Additional Four Year Compressor Warranty In addition to the one 1 year warranty stated above Turbo Air warrants its hermetically sealed compressor to be free from defects in both material and workmanship under normal and proper use and maintenance service for a period of four 4 additional years from the date of original installa...

Страница 10: ...ORTH IN THE WARRANTY PACKET PROVIDED WITH THE UNIT ALTERATION NEGLECT ABUSE MISUSE ACCIDENT DAMAGE DURING TRANSIT OR INSTALLATION FIRE FLOOD ACTS OF GOD Turbo Air is not responsible for the repair or replacement of any parts that Turbo Air determines have been subjected after the date of manufacture to alteration neglect abuse misuse accident damage during transit or installation fire flood or act...

Страница 11: ...11 Master bilt 908 Highway 15 North New Albany MS 38652 Phone 662 534 9061 Toll Free 800 647 1284 FAX 662 534 6049 Toll Free 800 232 3966 www master bilt com ...