2/20 Rev. A 57-02694
9
ELECTRICAL
WARNING
Before servicing electrical components in the case or the doors or door frames make sure all
power to case is off. Always use a qualified technician.
Check voltage and amps drawn on (
TABLE 2
) to determine proper line and fuse or circuit breaker size. Check power
supply for low voltage.
For example: If voltage reads “230” with no load, and it drops below “207” when the compressor tries to start, it is an
indication of too small supply wiring or too long to run.
It is recommended that a separate circuit be run for each cabinet to prevent another appliance blowing the fuse or
breaker, causing loss of product.
IMPORTANT
Models (3 door cabinet) are pre-wired internally with a 208-230V NEMA L14-20P plug and should only
be plugged into a NEMA L14-20P recepticle. See wiring diagrams for more details. The cabinet should
be grounded.
LEG / CASTER INSTALLATION
1. Screw legs / casters tightly into the rail
base mounting holes.