a) Installation

. The TP2400 may be installed in a standard 19” 

Rack, occupying 2 U (88.9mm) height, or on any shelf or location 
if the installation is fixed. In both cases make sure that the air flow 
is not blocked in any way.

Do not install inside closed locations without good air circulation.

b) Connection of pre-amplifier units

. For sound sources con-

nection, a professional Mixer with balanced outputs is strongly 
recommended. The outputs of this mixer should be connected 
to the TP2400 using XLR connectors (pin 1 shield, pin 2 live, pin 
3 return) to obtain the best performance. The connection cable 
should be twin conductor and shielded.

c) Connection of Loudspeakers

. Speakers of either 4, 8 or 16 

Ohm may be used provided the minimum total impedance of the 
amplifier (4 Ohm per channel) is maintained. Connect speakers 
in parallel for best results. Avoid combinations in series or series/
parallel. This will not cause any damage to the apparatus but can 
be detrimental to the general quality of the system.

To the Left and Right outputs the Mid-High frequency louds-
peakers (Satellites) may be connected. The power delivered by 
each of these outputs is of 500W at 4 Ohm, so the following 
combinations may be used:
-1 Speaker of 4 Ohm nominal impedance with a minimum power 
handling of 500W 
-1 to 2 Speakers of 8 Ohm with a minimum power handling of 
250W each, connected in parallel
-1 to 4 Speakers of 16 Ohm with a minimum power handling of 
125W each, connected in parallel.

At the Subwoofer output, the speaker system for the reproduc-
tion of low frequency should be connected. The power delivered 
at this output is of 1.400W at 4 Ohm, so 1 to 2 subwoofers of 
800W at 8 Ohm or 1 subwoofer of 1.400W at 4 Ohm may be 

used (e.g. 2 x 15” or 2 x 18”).

It is 

important

 to point out that the Limiter Adjust available for 

each channel allows the user to match the output delivered by 
the amplifier to the power handling of the available loudspeakers, 
when these ones have lower power handling.

For the loudspeaker connections, twin conductor cable with a 
minimum section of 4 mm should be used, or even greater if the 
distance between amplifier and loudspeaker exceeds 20 m.
Polarity (+/-) should be maintained throughout the installation. 
Phase inversion in any of the connected units will cause various 
frequency cancellations that will adversely affect the sound res-
ponse of the system.

IMPORTANT

: If for any reason a short-circuit may occur in any 

of the speaker lines, the short-circuit protection circuit lights the 
PROTECT LED (red) and completely cuts the power output of 
the affected channel until the fault is corrected. This guarantees 
protection of the speakers and power stages.

d) Location.

 The Mid-high frequency units (satellites) should be 

installed on specific stands more than 2m high (between 2.5 and 
4m). The best location for the Subwoofer units is at floor level in 

OPERATION

BACK PANNEL. CONNECTIONS

a) Signal inputs.

 The signal inputs require a XLR-3 connector. 

They are balanced using Pin 2 (XLR) as live (+), Pin 3 as return (-) 
and Pin 1 as shield (chassis).

IMPORTANT: If balanced signal is not available, DO NOT 
connect pins 1 and 3 together. Pin 1 should be left uncon-
nected and Pin 3 should be connected to the cable shield.

b) Loudspeakers.

 Loudspeakers are connected through BIN-

DING POSTS. 4 mm section multi -wire conductor are most 
recommended, being the polarity as follows: RED for the po-
sitive (+) loudspeaker’s terminal and BLACK for the negative (-) 
loudspeaker’s terminal. Outputs LEFT & RIGHT are available to 
connect the satellites or the Mid-high. The SUBWOOFER output 
is used to connect the low frequency reproduction speakers.

c) Mains 230V (+/-10%, 50-60Hz).

 The main connection is 

done with the supplied IEC/SCHUKO cable. It is recommended 
to always use the supplied cable, because it has the suitable 
cross section to hold the power drawn by the TP2400.

d) Ventilation.

 The TP2400 is cooled by forced ventilation by 

means of two fans located at the rear. The fans take the air in the 
amplifier from the back, and take it out through the grill on the 
front panel. Do not block the air intakes and outlets. The air flow 
is adjusted according to the temperature, starting at half speed 
and increasing it when the power modules or the mains transfor-
mer exceed 55º.

D

A

B

C

Содержание TP2400

Страница 1: ...INSTRUCTIONS MANUAL TP2400 THREE CHANNEL AMPLIFIER 2 1 SIGNAL PROCESSING Advanced sound systems since 1972...

Страница 2: ......

Страница 3: ...FER dispone adem s de interruptor BOOST que al activarlo aplica un incremento de 6dB a 50Hz se guido de un filtro subs nico de 18dB Oct muy til para reforzar la respuesta en graves sin comprometer la...

Страница 4: ...Right Una vez realizados volveremos a colocar el panel fron tal evitando que estos ajustes de mayor complejidad t cnica queden acce sibles al uso diario INDICADORES En el panel frontal se encuentran d...

Страница 5: ...n si la distancia supera los 20 metros Proc rese mantener la polaridad en toda la instalaci n Una inversi n de fase en alguna de las unidades conectadas provo car a cancelaciones entre los sistemas ac...

Страница 6: ...dores est n situados en el panel pos terior y disponen de dos velocidades de giro la inicial que co rresponde al 50 y est activada permanentemente y la total que corresponde al 100 y que se activa al...

Страница 7: ...es an increment of 6dB at 50Hz and a subsonic filter HPF of 18dB oct A very useful option when the response of the subwoofer needs to be reinforced without limiting the maximum admissible power Also i...

Страница 8: ...T RIGHT channels LPF and LIMITER can be adjusted Once these controls have been set the front panel cover can be mounted again to avoid and unintended change to these sensitive controls INDICATOR LEDS...

Страница 9: ...able with a minimum section of 4 mm should be used or even greater if the distance between amplifier and loudspeaker exceeds 20 m Polarity should be maintained throughout the installation Phase invers...

Страница 10: ...faulty or abnormal working condi tions caused by continued excess input signal Ventilation The cooling fans are located on the back panel and can operate at two speeds the initial speed is at 50 of th...

Страница 11: ...allation operation and maintenance detailed in this Manual have been strictly complied with Conditions exposed in the Certificate of Guarantee I Attach CERTIFICADO DE GARANT A Especificaciones sujetas...

Страница 12: ...Amate Electroac stica s l C Perpiny 25 08226 Terrassa BCN SPAIN Tel 34 735 65 65 Fax 34 735 60 48 export master audio com www master audio com...

Отзывы: