background image

  

 

 

 

 

 

 

 

Master Appliance Corp. 
2420 18

th

 St. 

Racine, WI  53403-2381    USA 

Tel:  262-633-7791 

Email: [email protected] 

www.masterappliance.com 

P/N 58266 REV A 

PAGE 2 OF 2 

 

     

Wings of ceramic 

element to be supported 
  by indents in nozzle 

 

 

 

Element Kits 

– Part No’s. 30082, 30083, 30084, 30085, 30086, 30087, 30088   

 

      

 

 
 
 
 
 
 
 
 

 

 

TOOLS REQUIRED 

 

TO REMOVE OLD ELEMENT 

1. Remove (3) nozzle mounting screws.  

 

2. Gently pull nozzle shield from gun housing. 

 

 

 

 

Models HG-201, HG-201A, HG-202, HG-202A, HG-301, HG-301A, HG-302, 
HG-302A, HG-501, HG-501A, HG-502, HG-502A, HG-501A-C, HG-501A-D, 
HG-751, HG-751A/15, HG-751A-20, HG-751A, HG-751B, HG-752, HG-752A, 
HG-751A-C, VT-750A, VT-752A, VT-750A-C, VT-752A-C, VT-750B, VT-750C, 
VT-752C, VTS-750, VTS-752

 

 

 

  

Do not touch 

nozzle until cool

 

Element 

  Mica 
Insulator 

Nozzle, 

not included in kit 

 

Indents support 
ceramic element

 

Nozzle Mounting Screw

(3), 

not included in kit

 

Flat Head Screw, 

remove to open cover

 

Round Head Screw, 

remove to open cover 

 

TO INSTALL NEW ELEMENT 

1. Attach element lead wires with new brass nuts furnished in 

replacement kit. Make sure they are tight for good electrical 

connection.  

 

2. Mount new element with pan head screw and rubber washer. 

Rubber washer must be mounted between element and 

mounting boss on housing. Be sure not to overtighten.  

 

 

THIS ELEMENT KIT CONSISTS OF:

 

 

ELEMENT, (1) 

 

MICA INSULATOR, (1) 

 

RUBBER WASHER, (1) 

 

BRASS NUT, #2-56, (2) 

 

SCREW, PAN HEAD, #4-40, (1) 

3. Remove screws on housing, 

 

and 

,

 (NOTE: Models 

 

4. Remove pan head screw and rubber washer holding 

element to housing, being careful that rubber washer 

does not fall back into the housing.  

 

5. Carefully lift element from its position exposing (2) 
    element nuts holding wires to element. Remove nuts 

    from element and disconnect wires. 

 

Pan Head Screw, 

Included in kit

 

Cover 

Element 

 

Brass Nuts, 

(2), included in kit 

Shield, 

not included in kit 

 

Rubber Washer, 

Included in kit

 

Element Lead Wires, 

Attach to new element 
with brass nuts 

 

Mounting Boss 
    in Housing 

Element Contacts, 

Must not touch each other and must not 
touch housing. Maintain a minimum gap 
of 1/8 inch. 

 

SLOTTED (FLAT) SCREWDRIVER

 

#1 PHILLIPS SCREWDRIVER

 

3/16” HEX WRENCH

 

              

WARNING:

 

Disconnect heat gun power cord and 

                               allow the heat gun to cool before disassembly. 

 

 
 

READ THE SERVICE INSTRUCTIONS CAREFULLY. FAILURE TO 
EXACTLY FOLLOW THE INSTRUCTIONS COULD RESULT IN 
PERSONAL INJURY OR DAMAGE TO YOUR HEAT GUN.  ALL 
REPAIRS MUST BE PERFORMED BY A QUALIFIED REPAIR 
TECHNICIAN. 

 
 

 
 
 

 

 

If nozzle mounting screws are lost or damaged, replace only with 
#6-40 steel machine screws, 3/16 inch minimum length to ¼ inch 
maximum length. 

 
 

 
 
 

 

 

 

 

 

 

 

 

 

3. Gently press element lead wires down under blower 

     wheel to prevent rubbing during operation.  

4. Discard the old mica insulator sheets and replace with 

corrugated mica insulator supplied in kit. Wrap mica 
insulator around coils of element, ensuring all coils are 
covered and attach housing cover.  

 

 

5. Attach cover screws loosely.  

 

& Ⓒ

 

6. Gently slide nozzle straight on, aligning ceramic element 
    with front nozzle indents and (3) rear nozzle screw 
    holes. Slide nozzle shield over nozzle, lining up 
    mounting holes. Install (3) mounting screws 
    loosely until started and then tighten. Tighten cover 

    screws.  

 

            

WARNING:

 

Failure to properly cover coils with 

               mica insulator could result in electrical short 

 
 

 

 
 

 
 
 

 

    

    

without the “A” or “B” suffix will 

not have the 

 

screw.) 

Cover can now be lifted away.

 