Masterflow

®

Parts List - All Models

Item No. Part No.

Description

1

815

Heating element only AH-301, 120V

816

Heating element only AH-302, 220/240V

30310

Heating element only AH-501, 120V

30311

Heating element only AH-502, 220/240V

30312

Heating element only AH-751, 120V

30313

Heating element only AH-752, 220/240V

2

823

Element bracket mounting screws (set of 2)

3

824

Bracket bar for AH-301, AH-302

825

Bracket bar for AH-501, AH-502, AH-751, AH-752

4

826

Bracket spacers for AH-301, AH-302 (set of 3)

51535

Bracket spacers for AH-501, AH-502, AH-751, AH-752 (set of 2)

5

827

Mica insulation for AH-501, AH-502, AH-751, AH-752

51376

Mica insulation for AH-301, AH-302

6

60066

Bracket washer for all (set of 4)

7

56012

Bracket screws for AH-301, AH-302, AH-501, AH-502, AH-751, 

AH-752 (set of 2)

8

833

Element wire mounting nut (set of 2)

9

836

Nozzle for AH-301, AH-302

837

Nozzle for AH-501, AH-751, AH-752

10

838

Nozzle screws (set of 3)

11

839

Nozzle shield for AH-501, AH-502, AH-751, AH-752

51207

Nozzle shield for AH-301, AH-302

12

842

Cordset, 120V  AH-301, AH-501

50924

Cordset, 120V  AH-501C, AH-751

843

Cordset, 220/240V (All models)

13

GRT-023

Strain relief

14

GRT-019

Strain relief

15

845

Switch only

16

846

Switch nut (furnished with switch)

17

847

Switch plate

18

805

Lead wire with thermal fuse, switch to element

19

50927

Thermal fuse with terminals and shrink sleeve

20

50737

Handle

21

56003

Handle screws (set of 4)

22

20108

Complete adjustable stand assembly

23

56021

Elastic stop nut

24

51008

Motor blower assembly, 120V

51009

Motor blower assembly, 220/240V

25

56075

Lockwasher (under 1 cover screw)

(When ordering, please specify part number and description.)

Masterflow

®

Heat Blower replacement parts and accessories are engineered and manufactured to precise

Master Appliance specifications. Replacement parts and accessories from other manufacturers are not pro-
duced to these precise specifications and, therefore, may cause difficulties with—or actual damage to—a
Masterflow

®

Heat Blower. Master Appliance cannot assume any responsibility or liability for difficulties result-

ing from the use of any other brand of replacement parts or accessories with a Masterflow

®

Heat Blower.

Содержание Heat Blower

Страница 1: ...usages industriels Dise adores y fabricantes de herramientas t rmicas para la industria Made in U S A Fabriqu aux tats Unis Hecho en EE UU Please read understand and keep this manual for future refere...

Страница 2: ...L INJURY 1 Read and understand this instruction manual before using Save this manual for future reference WARNING To reduce the risk of fire or electric shock do not expose heat blow ers to rain or mo...

Страница 3: ...air of electric tools a qualified service organization or our repair staff 21 WARNING This product when used for soldering and similar applications pro duces chemicals known to the State of California...

Страница 4: ...rs should not be present in the work area until the work is done and all cleanup is complete 6 Wear a dust respirator or a dual filter dust and fume respirator mask which has been approved by the Occu...

Страница 5: ...ble lead poisoning when strip ping this type of paint by using adequate ventilation such as a window fan in the exhaust mode and keeping a clean work area When dust or vapors are present use a respira...

Страница 6: ...gents turpentine gasoline lacquer or paint thin ner or other solvents that may contain chemicals which are harmful to plastics and other insulating materials Never immerse tool in a liquid or allow a...

Страница 7: ...7 Exploded View...

Страница 8: ...shield for AH 301 AH 302 12 842 Cordset 120V AH 301 AH 501 50924 Cordset 120V AH 501C AH 751 843 Cordset 220 240V All models 13 GRT 023 Strain relief 14 GRT 019 Strain relief 15 845 Switch only 16 846...

Страница 9: ...i dental or consequential damages from any defect in this product or its use Some states do not allow the exclu sion or limitation of incidental or consequential damages so the above exclusion may not...

Страница 10: ...300 220 240 5 2 AH 501 260 500 120 14 0 AH 502 260 500 220 240 7 3 AH 751 400 750 120 18 0 AH 752 400 750 220 240 9 4 Temp rature moyenne mesur e 25 mm 1 po de la buse AVERTISSEMENT CET APPAREIL CONST...

Страница 11: ...ne le tenez pas la main posez le souffleur sur une surface plate Placez le cordon de mani re viter le ren versement de l appareil 16 Ayez toujours un extincteur plein port e de la main 17 Surveillez...

Страница 12: ...l n est pas fini et tout le nettoyage termin 6 Portez un masque respira toire protecteur ou un masque respiratoire filtre double protection pous si res et vapeurs homo logu par l Administration de la...

Страница 13: ...aximale au terme d environ deux minutes Mode d emploi Lors du travail dans un con teneur ferm tel qu un tunnel de thermor tr cissement ou une enceinte sp ciale le souf fleur d air chaud doit tre con s...

Страница 14: ...eux au d capage de bois massif moulures tels les plinthes et garnitures d int rieur les portes balustrades et garnitures en bois massif de porches et v randas etc 1 Lors du d capage de sur faces peint...

Страница 15: ...TISSEMENT D branchez toujours votre appareil avant de proc der une op ration d entretien ou de r paration N utilisez que des pi ces de rechange de marque Master Appliance identiques celles enlev es Lu...

Страница 16: ...501 AH 502 AH 751 AH 752 51207 Cylindre protecteur de buse pour AH 301 AH 302 12 842 Cordon 120V pour AH 301 AH 501 50924 Cordon 120V pour AH 501C AH 751 843 Cordon 220 240V tous mod les 13 GRT 023 So...

Страница 17: ...on Certaines provinces interdis ent l exclusion ou la limitation des dommages fortuits ou cons cutifs il est donc possi ble que l exclusion ci dessus ne s applique pas votre cas La pr sente garantie v...

Страница 18: ...portantes instrucciones de seguridad El Masterflow Heat Blower es una herramienta de calidad industrial construido para tra bajos pesados y apto para servicio continuo La unidad produce un alto volume...

Страница 19: ...del cable 15 No remueva el pedestal ajustable Cuando la herramienta no se est sujetando con la mano col quela sobre una superficie nivelada Ponga el cable el ctrico de forma que no provoque el vuelco...

Страница 20: ...li dades de estrarlo y las madres lactantes no deben estar presentes en al rea de trabajo hasta que ste se haya acabado y todo est limpio 6 Llevar una mascarilla de respiraci n de polvo o una mascaril...

Страница 21: ...ici n vertical 4 Para apagar el soplador despu s de usarlo coloque el conmutador en la posici n de COLD fr o H galo funcionar en COLD por aproximada mente tres minutos Esto permitir que el soplador se...

Страница 22: ...mo Para informa ci n adicional vea neustras Instrucciones para remover la pintura 3 No utilice ninguno de los productos qu micos para remover pinturas Estos pro ductos con susceptibles de inflamarse y...

Страница 23: ...ier reparaci n o mantenimiento siempre desconecte su herramienta del suministro el ctrico S lo use las piezas de repuesto de la marca Master Appliance Lubricaci n Una vez al a o aplique 2 3 gotas de a...

Страница 24: ...24 Vista esquem tica...

Страница 25: ...Espaciador de soporte para AH 301 AH 302 juego de 3 51535 Espaciador de soporte para AH 501 AH 502 AH 751 AH 752 juego de 2 5 827 Aislamiento de mica para AH 501 AH 502 AH 751 AH 752 51376 Aislamient...

Страница 26: ...en su uso Algunos estados no permite la exclusi n o limitaci n de da os incidentales o emer gentes de manera que la exclusi n anterior puede que no afecte su caso Esta garant a le brinda derechos lega...

Страница 27: ...27...

Страница 28: ...aster Appliance Corp 2420 18th St Racine WI 53403 Tel 262 633 7791 Fax 262 633 9745 E mail sales masterappliance com Please visit our Web Site www masterappliance com Printed in U S A Form 58226 Rev 6...

Отзывы: