background image

00-05-3913

08

11

10

09

AC/DC Voltage Measurements

Warnings

Observe all safety precautions when working on live
voltages.
1

.

Put the

 

function

 

select switch to

 

audible.

2

.

Touch the test probes across the circuit being 

   measured.
3.The tester will turn on automatically if the voltage 
   exceeds 12 volts.
4.The LEDs will indicate the voltage.
5.For AC voltage, the “+” and “-” LEDs will illuminate.
6.For DC voltage, the “+” LED will illuminate if the
    instrument test probe is touching the positive side 
    of the circuit. The “-” LED will illuminate if the 
    instrument test probe is touching the negative 
    side of the circuit.
7.The buzzer will ring

 

when

 

the

 

Voltage

 

is

 

higher

 

  

than

 

about

 

50 volts.

Voltage LED steps
Accuracy

±12,24,50,120,230,400V

-30% to 0% of indication

Response time

AC frequency range

<0.1s

50/60Hz

Operation time

30 seconds maximum

Recovery time

10 minutes after 
maximum operation 
time has been reached

Temperature range

14

 to 131

(-10

 to 55

)

Relative Humidity

80% maximum

Altitude

7000ft(2000m)

safety

CAT III 400V

Weight

98.5g

Dimension

223*40*32 mm

Specifications

Maintenance

1.keep the tester dry. if it gets wet, wipe it off.
2.use and store the tester in normal temperatures. 
   temperature extremes can shorten the life of the 
   electronic parts and distort or melt plastic parts.
3.handle the tester gently and carefully. dropping 
   it can damage the electronic parts or the case.
4.keep the tester clean. wipe the case occasionally 
   with a damp cloth. do not use chemicals, cleaning 
   solvents, or detergents.

GFCI

 

Test

Warnings

Observe all safety precautions when working on live 
voltages.

 

The

 

GFCI

 

test

 

function

 

can

 

only

 

be

 

used

 

on

 

120

 

volt

 

AC

 

receptacles

 

with

 

GFCI

 

protection

.

1

.

Check

 

the

 

instructions

 

on

 

the

 

specific

 

GFCI

 

  

device

 

you

 

are

 

testing

 

before

 

proceeding.

2

.

Put the

 

function

 

select switch to

 

GFCI

 

test.

3

.

Press

 

the

 

test

 

button

 

on

 

the

 

GFCI

 

receptacle

.

  

The

 

GFCI

 

should

 

trip

If

 

not

do

 

not

 

use

 

the

 

  

receptacle

 

and

 

consult

 

a

 

qualified

 

electrician

  

If

 

it

 

does

 

trip

press

 

the

 

reset

 

button

 

on

 

the

 

  

GFCI

 

receptacle

.

4.Insert

 

one

 

test

 

probe

 

into

 

hot

 

side

 

of

 

the

 

outlet

 

  

being

 

tested

.

5

.

Insert

 

the

 

other

 

test

 

probe

 

into

 

the

 

ground

 

of

 

  

the

 

outlet

 

being

 

tested

.

6

.

The

 

tester

 

should

 

indicate

 

120VAC

 

if

 

the

 

outlet

  

 

is

 

powered

 

and

 

wired

 

properly

.

7

.

Press

 

the

 

GFCI

 

test

 

button

.

8

.

The

 

indicator

 

lights

 

should

 

turn

 

off

 

indicating

 

  

the

 

GFCI

 

has

 

tripped

.

9

.

If

 

the

 

GFCI

 

does

 

not

 

trip,either

 

the

 

receptacle

 

  

is

 

mis-wired

 

or

 

the

 

GFCI

 

is

 

defective.Do

 

not

 

use

 

  

the

 

receptacle

 

and

 

consult

 

a

 

qualified

 

electrician

.

Note

The

 

tester

 

cannot

 

test

 

GFCI

 

operation

 

on

 

2

-

wire

 

(non

-

grounded)

 

outlets

.

DONGGUAN

 

HUAYI

 

MASTECH

 

COMPANY

 

LIMITED

Yuliangwei

 

Industrial

 

Area

,

Qingxi

Dongguan

,

Guangdong

,

China

http

: //

www

.

p

-

mastech

.

com

Отзывы: