Mastech MS8910 Скачать руководство пользователя страница 4

3-3. LCD Display 
 

 

       

No.      Indicator 

Meaning 

SCAN 

  Auto    Scanning    Mode 

AUTO 

  Auto Ranging 

   

 

  Data Hold 

 

  Diode checking Mode 

`

 

  Continuity Checking Mode 

numF 

  Capacitance Units(nF, uF, mF) 

MK

Ω

 

  Resistance Units(

Ω

, K

Ω

, M

Ω

)

 

 

  Low Battery Indicator 

4. Specification 

4-1. General Feature 

    3000 count LCD display. 

    Full automatic measurement: 

        Auto scanning the Resistance/Capacitance/Diode. 

  Function selection by one “FUNC”    Push Button

 

  Data Hold function 

  Continuity Checking function 

  Over Load Indication ( ‘OL’) 

  Low Battery Indication 

  Power Supply: 3V Lithium Battery (CR2032) , 1pc 

  Test Pins is Gold-Plated. 

 

  Auto Power OFF. If the Tester is idle for more than 10 minutes,

 

   The Tester automatically turns the power off. 

   

  Operating  temperature  &  Humidity:  0  ~  40

(32  ~10

4 ℉

)    &  <  80% 

RH   

 

  Storage  temperature  &  Humidity:    -10  ~  50

    (14  ~  122 

)    & 

<70%RH

 

 

 ●

 

Safety Class:  IEC1010-1, CAT II 

  ● EMC: According to CE regulation 89/336. 

  Dimension (L x W x H) & Weight:    170 x 31 x 17mm,    Approx. 48.6 g 

  Environmental condition:   

1

Indoor use

   

2

Altitude up to 2000meter. 

 

 

Содержание MS8910

Страница 1: ...nd Indicators 3 1 Product Illustration 3 2 Push Buttons 3 3 LCD display 4 Specification 4 1 General Feature 4 2 Electrical Specification 5 Testing Operation 5 1 Scanning Mode 5 2 Resistance Measurement 5 3 Capacitance Measurement 5 4 Diode Check 5 5 Continuity Check 6 Maintenance 6 1 Replacing The Battery 6 2 Cleaning ...

Страница 2: ... thermo plastic elastomer and the two testing pins has been gold plated so that it is reduce pin contact resistance and prevent to get rusty This operating instruction covers information on safety and caution so please read relevant information carefully and observe all the warming and note strictly 2 Safety Note The following safety notes should be observed prior to using This Tester and any asso...

Страница 3: ...rm the Scanning Mode and then the SCAN and sign is displayed on the LCD This is indicate the Tester is inter to the auto scanning mode and will be automatically identify the resistor capacitor diode and continuity measurement mode The FUNC Button is used to selecting some one measurement mode manually 2 HOLD Press HOLD Button to enter or exit the hold mode In any measurement mode This key is act w...

Страница 4: ...ion by one FUNC Push Button Data Hold function Continuity Checking function Over Load Indication OL Low Battery Indication Power Supply 3V Lithium Battery CR2032 1pc Test Pins is Gold Plated Auto Power OFF If the Tester is idle for more than 10 minutes The Tester automatically turns the power off Operating temperature Humidity 0 40 32 104 80 RH Storage temperature Humidity 10 50 14 122 70 RH Safet...

Страница 5: ...canning mode and automatically identified the resistor capacitor diode and continuity and then enter to the corresponding measurement mode In the Scanning Mode when two pins are in touch with the object being measured the measured value will be displayed on the LCD Caution When measuring SMD device on the PCB You must be Disconnect power and discharge all high voltage Capacitors 5 2 Resistance Mea...

Страница 6: ...n touch with on the component cathode The measured value show on the LCD Reverse the test pin and measure the voltage across the diode again If diode is good the display shows OL If diode is shorted the display shows 0 zero in both direction If display shows OL in both direction the diode is open 5 5 Continuity Check May selecting Scanning Mode or Continuity Mode by FUNC push button When the resis...

Отзывы: