Mastech MS8239D Скачать руководство пользователя страница 8

11

12

 3.2.8 Engine Rev

 3.2.12 Diode

1mV

    

Display :read approximate

            forward voltage of diode.

 - Forward DC Current: approx. 1mA
 - Reversed DC Voltage: approx.1.5V
 - Overload Protection: 250V DC or rms AC

 4. Operating Instruction

4.1 Power-up

       

Press the “

ON/OFF

” button to turn the meter

        ON or OFF.

4.2 Data Hold

        If you need data hold when measuring, you can put 
        on “

DATA-H

” button, it will hold the reading; if you

        put the button again, data hold is not continue.

4.3 Maximum Value Hold

       If you need data hold when measuring, you can put 
       on 

“MAX. H”

 button, it will hold the maximum value; 

       if you put the button again, maximum value hold is
       not continue.

4.5 Back Light

       If the light is dark to make the reading 
       difficult when measuring, you can press 
       “     ” button for two seconds to turn on the
       back light, which will last for 15 seconds. 
       Continuous pressing the button for two
       seconds will turn off the back light.

4CYL

10RPM

Range

Resolution

    

±(

3.0% of rdg + 3 digits)

Accuracy

- Overload Protection: 250V DC or rms AC

6CYL
8CYL

10RPM
10RPM

Range

Function

4.4 Function Transform

       

Put down the "

FUNC

." when measuring the

        current and voltage. Meter will be transformed 
        between DC and AC range. Put 

"FUNC." 

when 

        measuring the temperature, meter will transform
        between and 

°

F range. Put 

"FUNC."

 when 

        measuring the diode and continuity, meter will 
        transform among them.

 Note:

 LED is the main source of back light. Its working 

  current is large, although the meter has the timer 
  equipment (time is 15 seconds and it will off 
  automatically after 15 seconds);often use back light 
  will shorten thebatteryife, you'd better not to use the 
  back light so frequently if it's not necessary.

When the battery voltage is less than 2.8V, it will

  show“      ”. But if you use back light at the same time,
  maybe “      ” will come up even if the battery voltage
  is more than 2.8V, because the working current is 
  higher and the voltage will decline. (When “      ”
  shows, the accuracy of the measurement can not be
  assured.)  You need not replace the battery. When 
  you use normally (back light is not using), “      ” will 
  not show up. You need replace it till “      ”show again.     

• 

Содержание MS8239D

Страница 1: ...MS8239D DIGITAL ENGINE ANALYZER OPERATOR S MANUAL HOLD MAX FUNC V 4CYL 6CYL 8CYL 8CYL 6CYL 4CYL DWELL TACH x10RPM 600V CAT III COM RPM DWELL 10A FUSED MAX 600V AUTO MAX DATA MS8239D ENGINE ANALYZER ...

Страница 2: ...ng Instruction 11 4 3 Maximum Value Hold 11 4 4 Function Transform 12 4 5 Back Light 12 4 6 Auto Power Off 13 4 8 Preparation For Measurement 13 4 9 Measuring Dc Voltage 13 4 10 Measuring AC Voltage 15 4 11 Measuring DC Current 15 4 12 Measuring AC Current 16 4 13 Measuring Resistance 16 4 14 Measuring Engine Dwell 17 4 15 Measuring Engine Rev 17 4 16 Diode Testing 18 4 17 Continuity Testing 18 5 ...

Страница 3: ...s and ranges disconnect test leads from the circuit under test 1 2 9 Never perform resistance temperature diode and continuity measurements on live circuits 1 2 10 Never use the meter under the condition of the explosive air steam or dirt 1 2 11 If any faults or abnormalities are observed the meter can not be used any more and it has to be checked out This instrument has been designed according to...

Страница 4: ...Before opening the battery cover or case of the meter always disconnect test leads from all tested circuits 1 4 3 To avoid the wrong reading causing electricity attack when the meter displays you must change the battery 1 4 4 Do not use abrasives or solvents on the meter use a damp cloth and mild detergent only 1 4 5 Always set the power switch to the OFF position when the meter is not in use 1 4 ...

Страница 5: ...tton is used to the switch of power RANGE Button This button is used to transform Auto range or manual range FUNC Button This button is used to transform function DATA H Button This Button is used to the switch of data hold MAX H Button This Button is used to the switch of maximum value hold Button This button is used to the switch of back light Transform Switch This switch is used to select funct...

Страница 6: ...ng of function and electrical capacity 3 1 11 Low Battery Indication displayed 3 1 12 Auto power off time 15 min 3 1 13 Power Supply 1 5V 2 AAAbattery 3 1 14 Operating Temperature 0 C to 40 C 32 F to 104 F 3 1 15 Storage Temperature 10 C to 50 C 10 F to 122 F 3 1 16 Dimension 150 74 42mm 3 1 17 Weight approx 250g including battery 08 3 2 1 Dc Voltage Input Impedance 10M Overload Protection 200mV r...

Страница 7: ... 10A voltage drop 2A range 20mV 10A range 200mV 3 2 5 Resistance 200Ω 2kΩ 20kΩ 200kΩ 2MΩ 0 1Ω 0 001kΩ 0 01kΩ 0 1kΩ 0 001MΩ 20MΩ 0 01MΩ Open Circuit Voltage 0 25V Overload Protection 250V DC or 250V rms AC Range Function Built in buzzer will sound if resistance is lower than 50Ω 20Ω Range Resolution 2 0 of rdg 10 digits Accuracy 3 2 4 AC Current 2 000A 10 00A 0 001A 0 01A 3 0 of rdg 10 digits Range...

Страница 8: ... digits Accuracy Overload Protection 250V DC or rms AC 6CYL 8CYL 10RPM 10RPM Range Function 4 4 Function Transform Put down the FUNC when measuring the current and voltage Meter will be transformed between DC and AC range Put FUNC when measuring the temperature meter will transform between and F range Put FUNC when measuring the diode and continuity meter will transform among them Note LED is the ...

Страница 9: ...ct the inner circuit from damaging Select a function and a range for the item to be measured through rotating the transform switch accordingly When the value scale to be measured is unknown beforehand set the range selector at the highest position When connection first connect to the public testing line then to the electriferous testing line When you ll remove it you should remove the elecriferous ...

Страница 10: ... range position 4 9 3 Put down the FUNC to enter the AC measurement 1 4 9 4 Connect test leads across the source or load under measurement 4 9 5 You can get reading from LCD 4 11 Measuring Dc Current Shut down the power of the tested circuit then connect the meter with the circuit for measurement Shut down the power of the tested circuit then connect the meter with the circuit for measurement 4 13...

Страница 11: ...he engine is started 4 16 Testing Diode 4 14 Measuring Engine Dwell 4 15 Measuring Rev 4 15 1 Connect the black test lead to the COM jack and the red test lead to the INPUT jack The polarity of red lead is 4 15 2 Set the transform switch at the range position 4 15 3 put down the FUNC transformed at test 4 15 4 Connect the red lead to the anode the black lead to the cathode of the diode under testi...

Страница 12: ...ING To avoid electric shock make sure that the test leads have been clearly move away from the circuit under measurement before opening the battery cover of the meter WARNING Do not mix old and new batteries Do not mix alkaline standard carbon zinc or rechargeable ni cad ni mh etc batteries If the sign appears it means that the batteries should be replaced Loosen the fixing screw of the battery co...

Отзывы: