DIGITAL MULTIMETER
OPERATING INSTRUCTION NTS
400mA and the maximum current of the 10A jack is
10A.
At the 10A jack, current exceeding the limit will
blow the fuse.
4.
4.
4.
4.19
19
19
19 MEASURING
MEASURING
MEASURING
MEASURING FREQUENCY
FREQUENCY
FREQUENCY
FREQUENCY
4.19.1 Plug the black test lead into the COM jack and the
red test lead into the Hz jack.
4.19.2 Set the rotary selector to the Hz range position (or
press the “Hz/DUTY” button at the AC/DC V range to
switch to Hz measurement).
4.19.3 Connect test leads to the two ends of the source or
load for measurement.
4.19.4 Take the reading on the main indicator of the LCD.
4.2
4.2
4.2
4.20
0
0
0 MEASURING
MEASURING
MEASURING
MEASURING DUTY
DUTY
DUTY
DUTY
4.20.1 Plug the black test lead into the COM jack and the
red test lead into the Hz jack.
4.20.2 Set the rotary selector to the Hz range position.
4.20.3 Press the "Hz/DUTY" button to switch to DUTY
measurement (or press the “Hz/DUTY” button at the
AC/DC V range to switch to DUTY measurement).
4.20.4 Connect test leads to the two end of the source or
load for measurement.
4.20.5 Take the reading on the main display of the LCD.
- 38 -
DIGITAL MULTIMETER
OPERATING INSTRUCTION NTS
4.
4.
4.
4.21
21
21
21 MEASURING
MEASURING
MEASURING
MEASURING RESISTANCE
RESISTANCE
RESISTANCE
RESISTANCE
WARNING
WARNING
WARNING
WARNING
Beware
Beware
Beware
Beware of
of
of
of Electrocution.
Electrocution.
Electrocution.
Electrocution.
When
When
When
When measuring
measuring
measuring
measuring in-circuit
in-circuit
in-circuit
in-circuit resistance,
resistance,
resistance,
resistance, make
make
make
make sure
sure
sure
sure that
that
that
that
the
the
the
the power
power
power
power of
of
of
of the
the
the
the circuit
circuit
circuit
circuit under
under
under
under test
test
test
test has
has
has
has been
been
been
been turned
turned
turned
turned
off
off
off
off and
and
and
and that
that
that
that all
all
all
all capacitors
capacitors
capacitors
capacitors have
have
have
have been
been
been
been fully
fully
fully
fully discharged.
discharged.
discharged.
discharged.
4.21.1 Plug the black test lead into the COM jack and the
red test lead into the
Ω
jack.
4.21.2 Set the rotary selector to the
Ω
range position.
4.21.3
Press the
"SELECT" button
to
switch
to
Ω
measurement.
Then press the “RANGE” button to
choose the auto range or manual range mode.
4.21.4 Connect the test leads to the ends of the resistor or
circuit for measurement.
4.21.5 Take the reading on the main indicator of the LCD.
NOTE:
NOTE:
NOTE:
NOTE:
1) At the manual range mode, when only ‘OL’ or ‘-OL’ is
shown on the LCD, it means the measurement has
exceeded the range.
A higher range should be
selected.
2) When the input is open, ‘OL’ will appear on the LCD to
indicate that the range has been exceeded.
3) For measuring resistance above 1MΩ, it may take a
few seconds to get a steady reading.
This is normal
for high resistance reading.