Mastech MS6501 Скачать руководство пользователя страница 14

symbol  will  appear  on  the  LCD  display  and  the  battery  need  to  be 
replaced.  Slide  the  battery  cover  away  from  the  instrument  and 
remove the battery. Replace with 9V battery and reinstall the cover 
 
 
 

6. OPTIONAL PROBE (TYPE K) 

TP-02A (optional): 

Measure Range: -50

 to 900

 (

-50

 to 1650

).

 

Dimension: 10cm tube, 3.2mm diameter. 

TP-03 (optional):   

Measure Range: -50

 to 1200

 (-50

 to 2200

).

 

Dimension: 10cm tube, 8mm diameter. 
 

>>>12<<< 

Содержание MS6501

Страница 1: ...field of precision measurements Although this Thermometer is a complex and delicate instrument its ruggedness will allow many years Of use if proper operating techniques are developed Please read the...

Страница 2: ...CONTENTS 1 FEATURES 1 2 FRONT PANEL DESCRIPTION 2 3 SPECIFICATIONS 3 4 MEASURING PROCEDURE 8 5 MAINTENANCE 11 6 OPTIONAL PROBE K TYPE 12...

Страница 3: ...ear read out even at bright places LCD display provides low power consumption LSI circuit use provides high reliability and durability High accuracy and wide measurement range Compact lightweight and...

Страница 4: ...2 FRONT PANEL DESCRIPTION Thermocouple input socket LCD display Function switch HOLD key 2...

Страница 5: ...d Operating principle dual slop integration Sample Rate 2 times sec for digital data Display 3 1 2 digits LCD Display with max Reading 1999 Automatic indication of functions Polarity indication displa...

Страница 6: ...pprox battery included TP 01 Thermocouple Probe The sensor supplied with the instrument is an ultra fast response naked bead thermocouple TP 01 suitable for many applications but with a maximum operat...

Страница 7: ...y are differentiated by A and B Their accuracy resolutions and measuring ranges are different You can find the measuring range from the meter s panel Measurement Range 50 0 to 150 0 58 to 302 A 50 to...

Страница 8: ...o 28O C 64O F to 82O F with relative humidity to 80 3 2 1 Celsius scale Range accuracy A B A B 50 0 to 40 0 50 to 40 6 6 39 9 to 20 0 40 to 20 3 5 19 9 to 0 20 to 0 2 3 0 to 99 9 0 to 500 1 0 75 2 100...

Страница 9: ...3 2 3 Fahrenheit scale Range accuracy A B A B 58 to 4 58 to 4 8 7 3 to 32 4 to 32 4 4 33 to 212 32 to 932 2 1 5 213 to 302 932 to 1382 4 0 75 4 7...

Страница 10: ...suitable probe of the K type can be used Insert the sensor plug into the socket at top edge of the instrument taking care to observe the correct polarity Select the function desired Use the sensing po...

Страница 11: ...y is to be achieved This will only take a couple of minutes and only applies if the sensor plug has previously been exposed to an ambient temperature different to that of the thermometer Note that in...

Страница 12: ...Allowable Error 0 TO 400 3 400 TO 1100 0 75 JIS C1602 1981 Measurement Temperature Class Allowable Error 0 1000 0 4 1 5 or 0 4 of Measured Temp 0 1200 0 75 2 5 or 0 75 of Measured Temp 200 0 1 5 2 5 o...

Страница 13: ...maintenance and repair shall be by a skilled person about temperature technology To maintain a thermocouple in good condition shall observe the following items Avoid excess bending Don t overheat the...

Страница 14: ...er away from the instrument and remove the battery Replace with 9V battery and reinstall the cover 6 OPTIONAL PROBE TYPE K TP 02A optional Measure Range 50 to 900 50 to 1650 Dimension 10cm tube 3 2mm...

Страница 15: ...WLS224...

Отзывы: