1. Safety Information

This meter has met IEC61010-1 and IEC-61010-2-032 
standards with an overvoltage category of 600V CAT III 
and a pollution degree of 2. Follow safe operation 
procedures to ensure the long life and safe use of this 
instrument.  

WARNING

1.1 Preparation

1.1.1 When using the meter, follow the following 
          safety rules:
          -Take precautions to prevent electrical shock
          -Do not misuse the instrument
1.1.2 Check the meter and accessories thoroughly 
          before using.
1.1.3 Check to see if the meter or any components 
          were damaged during shipment.
1.1.4 Inspect test leads and probes for cracks, breaks 
          or crazes on the insulation before using the meter.
1.1.5 Use test leads provided with the unit.  If 
          necessary, replace test leads with identical 
          specifications.

1.2 Usage

1.2.1 Turn the rotary switch to the required function 
          and range to be measured.
1.2.2 Never use the meter to measure voltages that 
          might exceed 600V DC/AC above earth ground.
1.2.3 Always be careful when working with voltages 
          above 60V DC or 30V AC RMS. Keep fingers 
          behind the probe barriers while measuring.
1.2.4 The “     ” symbol next to the input lead shows 
          that the input voltage or current should not 
          exceed the specified value in order to protect the 
          internal circuit from damage.
1.2.5 Choose the highest range when the value to be 
          measured is unknown.
1.2.6 Remove test leads before switching functions on 
          the rotary switch.
1.2.7 Do not perform resistance, capacitance, diode 
          and continuity measurements on powered circuits.
1.2.8 Never connect the test leads across a voltage 
          source while the rotary switch is in the resistance, 
          diode or continuity mode. Doing so can damage 
          the meter.
1.2.9 Power off the circuit and discharge capacitors 
          before testing capacitance.
1.2.10 Do not place the meter in any environment with 
            high pressure, high temperature, dust, explosive 
            gas or vapor.
1.2.11 Stop using the meter if any failure or abnormal 
            function is observed.
1.2.12 Do not use meter unless battery cover is in place 
            a secured.

TO REDUCE THE RISK OF FIRE, ELECTRICAL 
SHOCK, PRODUCT DAMAGE OR PERSONAL 
INJURY, PLEASE FOLLOW THE SAFETY 
INSTRUCTIONS DESCRIBED IN THE USER 
MANUAL. READ THE USER MANUALS 
BEFORE USING THE METER.

Содержание MS2140A

Страница 1: ... CAT ll 1000V A Hz MS2140A T RMS Inrush TEMP Hz μA Ω A V REL ZERO FUNC INRUSH HOLD RANGE MIN MAX COM Temp μAHz ΩV RELINP MAX MIN C kHz F µmVA nµmF MkΩHz AUTO K T NCV MAX 1000V Press 2Sec CAT lll 600V 600A TRMS AutoRange C US intertek 3080912 ...

Страница 2: ...rement 4 3 16 Backlight and Clamp light 4 4 17 Maximum Minimum recording 4 5 17 Function switching 4 6 17 ZERO REL 5 Maintenance 24 5 1 24 Replacing the batteries 5 2 25 Test Leads Replacement 6 25 Accessories 4 7 18 INRUSH 4 8 18 Auto Power Off 4 9 18 Measuring Preperation 4 10 19 Current Measurement 4 11 19 Voltage Measurement 4 12 20 Frequency and Duty Cycle 4 13 20 Resistance 4 14 21 Diode Tes...

Страница 3: ...oltages above 60V DC or 30V AC RMS Keep fingers behind the probe barriers while measuring 1 2 4 The symbol next to the input lead shows that the input voltage or current should not exceed the specified value in order to protect the internal circuit from damage 1 2 5 Choose the highest range when the value to be measured is unknown 1 2 6 Remove test leads before switching functions on the rotary sw...

Страница 4: ...he meter can be cleaned with a soft cloth to remove any oil grease or grime Do not use liquid solvent or detergent 1 4 5 When the instrument is not in use turn rotary switch to OFF 1 4 6 If the instrument is not to be used for an extended period of time remove the batteries to prevent damage to the instrument 1 4 Maintenance 2 Features and Components The CM660 is a portable hand held yet professio...

Страница 5: ...ets 7 Clamp trigger 8 Clamp for current measurement 2 1 Components 1 2 3 4 5 6 7 8 CAT ll 1000V A Hz MS2140A T RMS Inrush TEMP Hz μA Ω A V REL ZERO FUNC INRUSH HOLD RANGE MIN MAX COM Temp μAHz ΩV RELINP MAX MIN C kHz F µmVA nµmF MkΩHz AUTO K T NCV MAX 1000V Press 2Sec CAT lll 600V 600A TRMS AutoRange C US intertek 3080912 ...

Страница 6: ...w Battery NCV Ω kΩ MΩ 07 08 2 3 Display Description 2 2 Buttons and switches RANGE button backlight switch ranges in manual mode FUNC button switch measurement functions HOLD button hold reading on screen REL ZERO button relative reading DC zero offset INRUSH button measure Inrush current MAX MIN button switch between max min readings Rotary Switch switch between measurements INPUT jack voltage cu...

Страница 7: ... Size 238 92 50mm Weight 420g Including battery The Meter should be calibrated annually between 18 C 28 C and a relative humidity less than 75 3 1 General Specifications 3 2 Technical Specifications 3 2 1 True RMS Characteristics 3 2 1 1 For non sinusoidal signal measurements true RMS is a more accurate method of measurement over the averaging method 3 2 2 AC Current Accuracy Resolution Range 1 8 ...

Страница 8: ...ear before the test leads make contact with the circuit This is normal since the Meter is highly sensitive When the test leads are connected to the circuit the true reading will be shown Input impedance 10MΩ Maximum input voltage 600V AC RMS or 600V DC Frequency range 50 60Hz 600mV range only by pressing RANGE button 3 2 7 Frequency Accuracy Resolution Range 0 01Hz 60Hz Measuring range 10Hz 1kHz I...

Страница 9: ...ection 250V DC or AC RMS When measuring frequencies 60KHz duty cycle measurement range is 10 to 90 3 2 11 Capacitance Overload protection 250V DC or AC RMS 3 2 12 Diode Accuracy Resolution Range Forward DC current about 1mA Open circuit voltage about 2 8V Overload protection 250V DC or AC RMS 0 001V Displays approximate forward voltage Accuracy Resolution Range 3 2 10 Continuity Overload protectio...

Страница 10: ...rn on the display backlight the backlight will stay on for 20 seconds before it is automatically turned off 2 When the backlight is on press the RANGE for 2 seconds to turn off the backlight 3 In current mode turning on the backlight will also trigger the clamp light Note Backlight clamp light uses and LED even though the light will auto off after 20 seconds use only when needed to conserve power ...

Страница 11: ... difference of current reading and stored reading REL Output current reading reading when button pressed 2 REL can only perform under manual mode 4 6 ZERO REL 4 7 INRUSH When in AC Current measurement mode press the INRUSH button to enter surge current measurement mode Press button again to return to normal mode 4 8 Auto Power Off 1 When not in use the meter will automatically turn off after 20 mi...

Страница 12: ...sitivity of the Meter The Meter will display correct reading once the leads are connected to the circuit 4 12 Frequency and Duty Cycle 1 Insert the black test leads into COM input and red test lead into INPUT input 2 Turn rotary switch to Hz position 3 Connect test leads to the voltage source or between loads Note Frequency range is 10Hz 60MHz For frequencies below 10Hz display will show 00 0 For ...

Страница 13: ...tion and push FUNC three times for capacitance 3 Place leads at the terminals of the capacitor after it is fully discharged 4 Read the measurement from the display 4 17 Inrush Current Measurement 1 Turn rotary switch to A position 2 Push INRUSH button to enter inrush current mode 3 Open the clamp head by pressing the trigger and inserting the conductor to be measured 4 Power on the circuit being t...

Страница 14: ...e to a live conductor AC voltage 90V the NVC indicator will flash and buzzer will sound Note 1 Even though there is no indication voltage may still exist Do not rely solely on NCV detector to determine the presence of voltage in a wire The measurement may be affected by the design of the outlet type of insulation and other external factors 2 The voltage sensing indicator may turn on when a voltage...

Страница 15: ...ws Note Be sure to note the battery polarity when replacing 5 2 Test Leads Replacement REPLACE THE TEST LEADS WITH IDENTICAL OR COMPATIBLE LEADS LEAD SPEC 1000V 10A WARNING Replace new leads if the current leads are worn 6 Accessories 1 Test Leads Rating 1000V 10A 1 pair 2 User s Manual 1 pc 3 Batteries AAA Battery 3 pc 4 K type thermocouple 1 pc 5 Multi function socket 1 pc 00 05 3465 ...

Отзывы: