1. TECHNICAL PARAMETERS 

1.1    Input voltage :      104~127V AC (60Hz), 207~253V AC (50Hz) 

1.2    Line regulation:    CV

0.01%+1mV                CC

0.2%+1mA   

1.3    Load regulation:    CV

0.01%+3mV(I

3A) CC

0.2%+3mA(I

3A) 

                                                CV

0.01%+5mV(I>3A)    CC

0.2%+5mA(I>3A) 

1.4    Ripple and noise: CV

0.5mVr.m.s (I

3A)    CC

3mAr.m.s (I

3A) 

                                          CV

1.0mVr.m.s (I>3A)      CC

6mAr.m.s (I>3A) 

1.5    Protection: constant current and short-circuit protection 

1.6  Voltage  indication  accuracy:  LED/LCD

±

1%+2digits,  analogue 

Содержание HY1803D

Страница 1: ...USER S MANUAL DC REGULATED POWER SUPPLY ...

Страница 2: ...ng continuous adjustment of both the output voltage and output current levels The HY1500 and HY1800 series have LCD displays the HY1500C and HY1800C have analogue displays MODELS MODEL HY1502C HY1503C HY1802C HY1803C HY1505C HY1502 HY1503 HY1502D HY1503D HY1802D HY1803D HY1505D REGULAR OUTPUT VOLTAGE 0 15V 0 15V 0 18V 0 18V 0 15V 0 15V 0 15V ...

Страница 3: ...2 Line regulation CV 0 01 1mV CC 0 2 1mA 1 3 Load regulation CV 0 01 3mV I 3A CC 0 2 3mA I 3A CV 0 01 5mV I 3A CC 0 2 5mA I 3A 1 4 Ripple and noise CV 0 5mVr m s I 3A CC 3mAr m s I 3A CV 1 0mVr m s I 3A CC 6mAr m s I 3A 1 5 Protection constant current and short circuit protection 1 6 Voltage indication accuracy LED LCD 1 2digits analogue ...

Страница 4: ...CD 2 2digits analogue display 2 5 1 8 Environment 0 40 0 C relative humidity 90 2 OPERATION 2 1 Front panel controls 1 Current indication 2 Voltage indication 3 Coarse adjustment of current 4 Coarse adjustment of output voltage 5 Negative output terminal ...

Страница 5: ... OFF switch 7 and adjust controls 4 to set the desired output voltage Connect the load to the output terminals 5 6 2 2 2 For constant current mode adjust controls 4 clockwise to the maximum position Adjust controls 3 anti clockwise to the minimum position Switch on the power ON OFF switch 7 and connect the load to the output terminals 5 6 Adjust controls 3 to set the desired output ...

Страница 6: ...put terminals 5 6 Adjust controls 3 clockwise to set the output current at the desired level for restricted current protection 3 ATTENTION 3 1 In the event of a short circuit at the output the current will limit at the value set by the current controls however the unit should be turned off and the short circuit removed before continuing use 3 2 The mains power must be switched off before servicing...

Страница 7: ... 6 3 3 The unit should be stored in a dry and well ventilated place and the power cord removed if storing for long periods 4 ACCESSORIES 4 1 Power cord one piece 4 2 Instruction manual one piece ...

Отзывы: