background image

1.RCA INPUT / AUTO HI-LOW LINE CONVERTOR

RCA input jacks are for use with source units that have outputs up to 5V. A 
remote  turn  on  wire  is  needed  when  not  using  the  ATO  feature.  When  a 
remote turn on wire is used keep the ATO button pressed “in”. For Hi-level 
signal input use non-supplied RCA speaker wire adaptors. Connect positive 
and negative of each speaker to each adaptor and connect to RCA inputs. 
Press ATO button “in” (see #6) when hi-level signal is used.
 

2.X1 / X18 FOR HIGH PASS FREQUENCY CROSSOVER

When this button is set at the “out” position the HPF range adjustments are 
20Hz ~ 45KHz. When this button in set at the “in” the HPF range is from 
360Hz ~ 6KHz. WARNING: Use buttons and HPF knob correctly to prevent 
low frequency damage to tweeters. 

3.HI-PASS FILTER AND MODE SWITCH

When the setting is adjusted to the far left position the amplifier is in full 
range from 20Hz ~ 45KHz. Adjustments to HPF can be made by turning to 
the right to desired frequency.
 

4.X1 / X11 LOW PASS FREQUENCY CROSSOVER

When this button is set to the “out” position the LPF range adjustments are 
50Hz ~ 550Hz. When this button is set to “in” the LPF range is from 550Hz 
~ 6KHz.

5.LOW PASS FILTER CONTROL 

This control is used to select the desired low pass x-over frequency. The 
frequency can be adjusted from 50Hz to 6KHz.

6.AUTO TURN ON SIGNAL SENSING HI-INPUT / REMOTE OUT

When  ATO  button  is  set  to  “in”  any  RCA  low  level  signal  coming  from  a 
source will turn on the amplifier. Optional turn on of the amp can be done 
using  the  12Volt  turn  on  terminal  (see  #16)  if  desired.  When  set  to  the 
“out” position speaker level inputs using the non-supplied  RCA speaker wire 
adaptors  will  automatically  power  on  the  amplifier  and  the  remote  input 
becomes a 12V DC trigger output to power other 12V devices. 

7.POWER INDICATOR

When LED is GREEN this amplifier is in safe operation. When LED is RED this 
amplifier is in protection mode. 

8.GAIN CONTROL

The  gain  control  will  match  the  amplifiers  sensitivity  to  the  source  units 
signal voltage. The operating range is 6V to 200mV. Input level is from 0.2V 
~ 5V.  This is NOT a volume control. 

9.SETTING FOR HPF / FR OR LPF / BAND PASS

When  this  button  is  set  to  the  “out”  position  frequencies  are  either  full 
range  or  high-pass  depending  on  your  frequency  selector  settings  (#2  & 
#3). When button is set to “in” frequencies are low-pass and  adjustable for 
the  creation  of  a  band-pass  depending  on  your  high-pass  /  low-pass 
frequency selector settings. For band-pass use (#2, #3, #4 & #5)

Отзывы: