INSTALLATION

Minimum ceiling height is 36" / 914 mm from top of unit.

If further reduced clearances are needed, obtain requirements for construction of a protected wall from your local building
authorities and their allowable reductions of the listed clearances.

CLEARANCES  TO COMBUSTIBLES

Note: Not intended for fireplace insert.

The clearances listed below are MINIMUM distances.  Measure the clearance to both the appliance and the chimney connector.
(The farthest distance is correct if the two clearances do not coincide.) For example, if the appliance is set as indicated
in one of the figures but the connector is too close, move the stove until the correct clearance to the connector is obtained.

This unit can be installed on a solid combustible surface like a wood floor.This unit can also be installed directly on carpeting
or vinyl when the bottom pedestal cover plate (provided with unit) is installed.

This appliance may be installed only with the clearances as shown in the situations pictured.  Do not combine clearances from
one type of installation with another in order to achieve closer clearances.

Use the minimum clearances shown in the diagrams below for installation with a standard 100mm flue.

F43-NG & F43-LP Clearances

F43-NG & F43-LP Clearances

F43-NG & F43-LP Clearances

F43-NG & F43-LP Clearances

F43-NG & F43-LP Clearances

A Side Wall to Unit

7-1/2" / 190 mm

B Back Wall to Unit 6" / 155 mm

E Side Wall to Unit

2" / 50 mm

F28-NG & F28-LP Clearances

A Side Wall to Unit

7-1/2" / 190 mm

B Back Wall to Unit 6" / 155 mm

E Side Wall to Unit

2" / 50 mm

F43-NG & F43-LP Reference Dimensions

F43-NG & F43-LP Reference Dimensions

F43-NG & F43-LP Reference Dimensions

F43-NG & F43-LP Reference Dimensions

F43-NG & F43-LP Reference Dimensions

C Back Wall to Flue Centerline

10-1/2" / 265 mm

D Side Wall to Flue Centerline

22-1/8" / 562 mm

F Side Wall to Flue Centerline

11" / 280 mm

F28-NG & F28-LP Reference Dimensions

C Back Wall to Flue Centerline

10-3/4" / 273 mm

D Side Wall to Flue Centerline

20-1/2" / 520 mm

F Side Wall to Flue Centerline

11" / 280 mm

Содержание Geneva

Страница 1: ... any other appliance Installation and service must be performed by an authorized installer service agency or the gas supplier PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE Owners Installation Manual LISTINGS AND CODE APPROVALS Thesegasapplianceshavebeen tested in accordance with AG 103 NZS 5262 and have been certified by the Australian Gas Association for installation and operation as descri...

Страница 2: ...G F43 LP F28 NG and F28 LP of this series has been approved by Australian Gas Association for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many features of your Masport Gas Stove F43 NG F43 LP F43 NG F43 LP F43 ...

Страница 3: ...eplacement 19 Door and Glass Gasket 19 Gold Plated Doors 19 Glass Replacement 20 Fan Maintenance F43 21 Fan Maintenance F28 22 Removing Valve 23 Troubleshooting Guide 25 Parts List F43 26 Parts List F28 29 Warranty Warranty 35 Safety Label Data Plate 4 Installation General Installation Information 5 Installation Checklist 6 Draft Diverter 6 Flueing 6 Flueing Requirements 6 Minimum Clearances to Co...

Страница 4: ...f the label that accompanies each Masport F43 Freestanding Gas Heater We have printed a copy of the contents here for your review DATA BADGE NOTE Masport units are constantly being improved Check the label on the unit and if there is a difference the label on the unit is the correct one ...

Страница 5: ...onnected to a flue and terminate to the outside of the building envelope Never flue to another room 5 Inspect the flueing system annually for blockage and any INSTALLATION THIS APPLIANCE SHOULD BE INSTALLED REPAIRED INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY AN AUTHORISED SERVICE PERSON MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING ETC IT IS IMPER ATIVE THAT CONTRO...

Страница 6: ...liance see data badge b Adjusting the primary air if required to ensure that the flame does not carbon See page18 c Ensuring that the appliance is flued and operating correctly See page 8 CAUTION Any alteration to the product that causes sooting or carboning or that results in damage is not the responsibility of the manufacturer DRAFT DIVERTER This heater has a draft diverter built in It must not ...

Страница 7: ...h unit is installed This appliance may be installed only with the clearances as shown in the situations pictured Do not combine clearances from one type of installation with another in order to achieve closer clearances Use the minimum clearances shown in the diagrams below for installation with a standard 100mm flue F43 NG F43 LP Clearances F43 NG F43 LP Clearances F43 NG F43 LP Clearances F43 NG...

Страница 8: ...fan 125 75 CFM Log Set Ceramic fiber 3 per set System Data F28 NG F28 LP INSTALLATION GAS CONNECTION The gas line can be rigid pipe or to make installation easier use a listed flexible connector if allowed by local codes Copper may also be used if approved by local codes The gas connection at the valve is 1 2 inch BSP For minimum and maximum supply pressure see the System Data Table GAS PIPE PRESS...

Страница 9: ...tion The gas log kit contains the following a Front Right Log b Front Left Log c Rear log d Embers 1 Remove the logs from the box and carefully unwrap them The logs are fragile handle with care DO NOT FORCE into position 2 Place the rear log carefully sliding it down onto the pins with the flat side of the log facing the back of the unit See diagram 1 3 Place the left front log carefully sliding i...

Страница 10: ...11 d Embers Part 902 151 1 bag Part 560 933 for the set of three logs 1 Remove the logs from the box and carefully unwrap them The logs are fragile handle with care DO NOT FORCE into position 2 Place the rear log carefully sliding it down onto the pins with the flat side of the log facing the back of the unit See diagram 1 Note Do not force logs down 4 Place the right front log carefully sliding i...

Страница 11: ...he proper setting If they are too hard or too easy to close you may want to adjust them by loosening the latch catch See diagram 3 5 Remove the blue plastic protective coating from the glass 6 Test the seal around the door by placing a piece of paper between the unit and the door close the door and try to pull the paper out If it slips out easily then the door is not properly sealed Tighten or loo...

Страница 12: ... or similar device which gives off smoke on the edge of the draft diverter See diagrams The thermally activated safety switch must be manually reset before first startup The smoke should be drawn into the draft diverter If the smoke is not drawn into the draft diverter turn the unit off and check for the cause of lack of draft Note If the flue is blocked or has a strong reverse flow the thermally ...

Страница 13: ...13 Masport F43 F28 Freestanding Gas Heater WIRING DIAGRAM F43 WIRING DIAGRAM F28 INSTALLATION ...

Страница 14: ...he Masport Remote Control Kit Part 910 358 P approved for this unit Use of other systems may void your warranty The remote control kit comes with a hand held transmitter a receiver and a wall mounting plate 1 Choose a convenient location on the wall to install the receiver and the receptacle box protection from extreme heat is very important Run wires from the fireplace to that location Use Thermo...

Страница 15: ...t it may causecondensationandfogtheglass Thiscondensa tionisnormalandwilldisappearinafewminutesasthe glassheatsup DO NOT BURN THE APPLIANCE WITHOUT THE GLASS FRONT IN PLACE OPERATING INSTRUCTIONS Before operating this appliance proceed through the following check list 1 Read and understand these instructions before operating this appliance 2 Clean the burner and control compartment of lint and hou...

Страница 16: ...pop up when released stop and immediately call your service technician or gas supplier If the pilot will not stay lit after several tries turn the gas control knob to OFF and call your service technician or gas supplier 5 Turn gas control knob counterclockwise to ON 6 Use rocker switch to operate main burner 908 649 OFF WARNING If you do not follow these instructions exactly a fire or explosion ma...

Страница 17: ...nto proper contact with the rear burner or thermo pile ADJUSTING FLAME HEIGHT Your heater has an adjustable flame to tailor the look and heat output to your specific needs It is adjusted by turning the flame adjustment dial on the gas control valve Turn clockwise to adjust the flame higher counterclockwise for a lower flame OPERATING INSTRUCTIONS WARNING DO NOT SPRAY AEROSOLS IN THE VICINITY OF TH...

Страница 18: ...itch contacts closing and is normal Pilot Flame While the pilot flame is on it can make a very slight whisper sound Gas Control Valve As the gas control valve turns ON and OFF a dull clicking sound may be audible this is normal operation of a gas regulator or valve Unit Body Firebox Different types and thicknesses of steel will expand and contract at different rates resulting in some cracking and ...

Страница 19: ...loth Never use an abrasive cleaner The gold louvres and optional gold door may be scratched if abrasives are used to clean them The heater is finished in a heat resistant paint and should only be refinished with heat resistant paint not with wall paint Regency uses StoveBright Paint Metallic Black 6309 3 Make a periodic check of burner for proper position and condition Visually check the flame of ...

Страница 20: ...e glass retainers on sides first 3 each side then remove two center retainers Note Center glass retainers are glued to center glass 6 Remove glass from aluminium extrusions When remov ing center glass leave white insulation in place 2 Place glass assembly into door frame 3 Install retainers by placing 1 drop of glue where previous ly glued and put in place 4 Install side retainers 5 Install door c...

Страница 21: ...ecurelyinplaceandcorrectlysealed IMPORTANT These fans collect a lot of dust from within your home Ensure you maintain these fan motors on a regular basis by vacuuming out the fan squirrel cages around the motor and around the grills on the back of the stove IMPORTANT Disconnect power supply before servicing ing prong from this plug To remove F43 fan 1 Unplug or disconnect power source to stove WAR...

Страница 22: ...ight side by opening the right side door See Diagram 2 3 Unclip the black red and white wires from the fan motor 4 Lift fan off of the 2 pins tip back and pull through firebox opening Disconnect the green ground wire from the left side of the fan as soon as you can reach it Diagram 1 Diagram 2 Replacing F28 Fan Reverse the above steps 1 4 If necessary install a new gasket before replacing the fan ...

Страница 23: ...ain You may want to put a soft cloth on the base of the unit so that when the pedestal door is open it doesn t scratch the paint See diagram below 2 Undo the six screws holding the control panel in place 3 Disconnect all wires from the back of the panel and then remove panel You should lay the panel on a soft cloth so it doesn t get marked up See diagram below 4 Remove the two outside frame pieces...

Страница 24: ...s at the valve 7 Remove the burner by removing the four 1 4 hex head screws See diagram below Note Use a magnetic type screwdriver 8 Remove eight 1 4 hex head screws holding the burner tray assembly in place 9 Carefully lift the burner tray assembly out F43 Burner F28 Burner 10 To replace the burner tray assembly simply reverse these instructions ...

Страница 25: ...ilot is enveloped around thermopile and thermocouple Be sure wire connections at gas valve terminals are tight and ther mopile and thermocouple are fully inserted into pilot bracket One of the switch wires may be grounded May be grounded to gas appliance or gas supply Check thermopile with millivolt meter Take reading at thermopile terminals of valve TP TPTH Should read 250 millivolts minimum whil...

Страница 26: ...d by an approved Masport Service Agent This Express Warranty Does Not Cover 1 Defects malfunctions or failures caused by incorrect installation normal wear and tear misuse neglect accidental damage or failure to follow the fuel selection product operating and maintenance instructions or re sulting from installations repairs or modifications to the equipment carried out by unauthorised persons 2 De...

Отзывы: