![Maspo Beauty Skin Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/maspo/beauty-skin/beauty-skin_operating-instruction_1735335012.webp)
12
GB
Replacement of the
fl uorescent tu-
bes
Replacement is easy and is done as fol-
lows:
(please use only original Dr. Kern Lamps)
Replacement of the starters
• It is very easy to replace the starters. The
starters should be renewed along with
every lamp replacement. The starter is
removed from its base through light down-
ward pressure and minimal rotation to the
left.
Maintenance
Technical data
Supply voltage: 230 V
Type of lamps: Dr. Kern Special Fluorescent
lamps blue (spectrum 400-450 nm)
red (cpectrum 580-659 nm)
Power of lamp: 15 W
Length of lamp: 29 cm
Number of lamps: 6
Power consumption: 100 W
Repair
• Repairs in and on the unit should be done
only by an expert.
Our service address is listed on the page
where warranty is specifi ed.
• Unscrew the 4 fastening bolts on the back
panel of the unit and remove the panel.
• Turn each lamp as far as necessary to
enable it to be removed towards the front
from the base slots.
• Replace with new lamps by pushing the
contact pins above and below into the
base slots at the same time and fi nally tur-
ning the lamps one quarter turn on their
axes.
Always remove plug from the wall
socket.
• Wipe the lamps and the
refl ector off regu-
larly with a dry, soft cloth.
• The red and blue fl uorescent lamps were
especially developed with the required
wavelength for BEAUTY SKIN. They are
available only from Dr. Kern. The fl uore-
scent lamps should be replaced after 250
operating hours.
Always remove plug from the wall
socket.
Always remove plug from the wall
socket.
Service life of the lamps
Dr. Kern Special Fluorescent Lamps have a
maximum service life of 250 hours. After this
time they still glow; however, the radiation is
weakened to such a degree that the tubes
should be replaced.
Содержание Beauty Skin
Страница 2: ...2 Deutsch 3 English 9 Русско 15 ...