17
Heating and cooling option
Special versions of MasoSine C100, C200, C250, C300 and
C400 pumps can be heated or cooled to maintain the required
product temperature within the pump—pumping chocolate or
ice cream, for example—by passing fluid at the temperature
required through crescent-shaped channels in the pump
housing and the front housing. The pump has 1/8in
connections on two sides though which the heating or cooling
agent flows. The position of the connections varies depending
on the model. A possible backpressure should not exceed
1bar/15psi. The minimum flow required for the heating/cooling
option is 0.2l/min or 0.05gpm.
Note:
Most pump sizes can be retro-fitted to allow heating
and cooling (refer to table below).
Note:
The heating or cooling temperature must stay within
the temperature limits of the pump. These can be found in See
Limit values for the pump on page 9
C100
C200
C250
C300
C400
Pump
housing
MP-HZG-G-C100
MP-HZG-G-C200
MP-HZG-G-C250
MP-HZG-G-C300
MP-HZG-G-C400
Front
cover
MP-HZG-D-C100
MP-HZG-D-C200
MP-HZG-D-C250
MP-HZG-D-C300
MP-HZG-D-C400
m-certa-en-08
25